Recommended for advanced users only
Provides an internal instance variable name to be inserted. The path is relative to the object triggering the alert
|
%{ALARM_TYPE}
|
Type of alert triggered (ALARM, WARN or INFORMATION)
|
%{ASCTIME:…}
|
Current date and time formatted as specified in the macro
|
%{CONTEXT}
|
Path of parent instances up to the root path
|
%{DATE}
|
Current date in the YYYY-MM-DD format
|
%{HOSTNAME}
|
Hostname of the storage system in an abnormal state.
If the alert is triggered on the SMI-S provider, the hostname of the SMI-S Provider will be displayed and if the alert is triggered on the main instance, the PATROL Agent hostname will be displayed.
|
%{IP_ADDRESS}
|
IP Address of the storage system in an abnormal state.
If the alert is triggered on the SMI-S provider, the IP address of the SMI-S Provider will be displayed and if the alert is triggered on the main instance, the PATROL Agent IP address will be displayed.
|
%{NEWLINE}
|
Linefeed. This is useful to produce multi-line information
|
%{OBJECT_CLASS}
|
Class of the instance that triggered the alert
|
%{OBJECT_ID}
|
PATROL internal ID of the instance that triggered the alert
|
%{OBJECT_LABEL}
|
Display name of the instance that triggered the alert
|
%{OBJECT_TYPE}
|
Type of the instance (Fiber Port, Ethernet Port, Storage System, ... )
|
%{PARAMETER_NAME}
|
Name of the parameter that triggered the alert
|
%{PARENT_...}
|
Gets the parent's object of a macro
|
%{PARENT_CLASS}
|
Class of the object that the faulty instance is attached to
|
%{PARENT_ID}
|
PATROL internal ID of the object that the faulty instance is attached to
|
%{PARENT_LABEL}
|
Display name of the object that the faulty instance is attached to
|
%{PROBLEM}
|
Displays the nature of the problem in plain English including the following information:
Problem detected with <OBJECT_TYPE> <OBJECT_NAME>: <PARAMETER_NAME> = <PARAMETER_VALUE> <PARAMETER_UNIT> ==> <PARAMETER_STATE>.
|
%{TIME}
|
Current time in the HH:MM:SS format
|
%{VALUE}
|
Formatted value (with unit) of the parameter that triggered the alert
|