SEN_EMC_FILESYSTEM

Home  Previous  Next

Icon

sen_emc_filesystem_ok_32

Parameters

noteThis Monitor type is only available for EMC Celerra storage systems

Name

Description

Units

Default Alert Conditions

Attribute Type

AvailableCapacity

Total capacity not consumed in the file system.

Gigabytes (GB)

None

Statistics

AvailableCapacityPercentage*

Percentage of capacity not consumed in file system.

Percentage (%)

None

Statistics

CIFSShareStatus*

Status of the CIFS share.

{0=OK; 1 = Degraded; 2 = Failed}

Warning = 1
Alarm = 2

Availability

CIFSShareStatusInformation

Detailed information about the CIFS share status.

n/a

None

--

CIFSSharingElements

List of the CIFS Shared.

n/a

None

--

ConsumedCapacity

Number of bytes actually consumed in the file system.

Gigabytes (GB)

None

Statistics

ConsumedCapacityPercentage

Percentage of the capacity that is actually consumed in the file system.

Percentage (%)

None

Statistics

NFSExportStatus

Status of the NFS export.

{0=OK; 1 = Degraded; 2 = Failed}

Warning = 1
Alarm = 2

Availability

NFSExportStatusInformation

Detailed information about the NFS Export status.

n/a

None

--

NFSSharingElements

List of the NFS Shared.

n/a

None

--

Status*

Status of the file system.

{0=OK; 1 = Degraded; 2 = Failed}

Warning = 1
Alarm = 2

Availability

StatusInformation

Provides detailed information about the file system status.

n/a

None

--

*Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.

InfoBox

Name

Description

PATROL ID

The PATROL internal identifier.

Block Size

Size of a block in the file system.

Capacity

Number of bytes available in the file system.

Caption

Short description containing the name of the file system.

MetaTokenID

Identifier of the instance. This identifier is required to ensure the instance is properly interpreted by BMC TrueSight Operations Management.

CI_ID

Identifier of the configuration item.

Menu Commands

Function

Description

Pause Monitoring

Pauses the monitoring of the selected object.

Resume Monitoring

Resumes the monitoring of the selected object.

Remove