EMC XtremIO Local Disk
PATROL Class: SEN_XTRM_LOCALDISK - Monitor Type: MONITOR - Monitor Category: System
CDM Class: BMC_DiskDrive
Monitors a specific local disk drive.
Attributes (Parameters)
| Name | PATROL Name | Units | Default Thresholds | Description |
|---|---|---|---|---|
| Bad Sectors Count | BadSectorsCount | bad sectors | None | Number of bad sectors. Type: Statistics |
| Enable Status | EnableStatus | 0 = Enabled 1 = User Disabled 2 = System Disabled 3 = Unknown |
WARN ALARM |
Indicates whether the local disk is currently enabled or disabled. Type: Availability - Spikes expected |
| FRU Lifecycle Status | FRULifecycleStatus | 0 = Healthy 1 = Initializing 2 = Failed/Disconnected/Uninitialized 3 = Unknown |
WARN ALARM |
Local disk's Field-Replaceable Unit (FRU) status. Type: Availability - Spikes expected |
| Object Severity | ObjectSeverity | 0 = Clear/Information 1 = Minor 2 = Major/Critical 3 = Unknown |
WARN ALARM |
Local disk's severity, based on severity level of current alerts. Type: Availability - Spikes expected |
| Present | Present | 0 = No 1 = Yes |
ALARM |
Indicates whether the device is present or not since the last collect. Type: Availability - Spikes expected |
| Status Information | StatusInformation | None | None | Detailed information about the local disk status. Type: Text |
Infoboxes (PATROL Console Only)
| Name | Description |
|---|---|
| PATROL ID | The PATROL internal identifier. |
| Model | Local disk model. |
| Type | Local disk type. |
| Serial Number | The local disk's serial number. |
| Purpose | Local disk purpose. |
| Firmware Revision | Version of the local disk's firmware. |
| Slot Number | Slot index in which SSD currently resides, or Slot index into which the currently-disconnected SSD was previously inserted. |
Menu Commands (PATROL Console Only)
| Menu Command | Description |
|---|---|
| Acknowledge Error Count Alerts and Reset | Acknowledges the alert and resets the error count to zero. |
| Pause Monitoring | Pauses the monitoring of the selected object. |
| Resume Monitoring | Resumes the monitoring of the selected object. |
| Remove | Removes the selected object from the monitoring environment. |
xtremio km patrol