Hardware Enclosure
PATROL Class: MS_HW_ENCLOSURE - Monitor Type: MONITOR - Monitor Category: System
CDM Class: BMC_ComputerSystem -- Instances of this monitor will be represented as devices in TrueSight Operations Management
Monitors a hardware enclosure, such as a computer's main chassis, external disk arrays or blade enclosures.
Attributes (Parameters)
| Name | PATROL Name | Units | Default Thresholds | Description |
|---|---|---|---|---|
| Intrusion Status | IntrusionStatus | 0 = OK
2 = Intrusion Detected |
None |
Monitors the intrusion status of the enclosure. If the enclosure is open or not properly closed, it is set to Intrusion Detected. Value set by enclosureColl. Type: Availability |
| Power Consumption | PowerConsumption | Watts | None |
This parameter reports the electricity consumption. Value set by enclosureColl. Type: Statistics - Default graph |
| Power State | PowerState | 0 = Off
1 = Suspended 2 = On |
None |
The enclosure current power state: on, off or suspended. Value set by enclosureColl. Type: Availability |
| Present | Present | 0 = Missing
1 = Present |
ALARM
|
Indicates whether the enclosure is found or not. Value set by enclosureColl. Type: Availability |
| Status | Status | 0 = OK
1 = Degraded 2 = Failed |
WARN
ALARM
|
Current status of the enclosure. Value set by enclosureColl. Type: Availability |
| Status Information | StatusInformation | None | None |
Additional (textual) information about the current status of the enclosure. Value set by enclosureColl. Type: Text |