date_published: 2026-11-09
date_modified: 2026-11-09
---

 [Back to the list of classes](km-reference.html)

## Hardware LUN

PATROL Class: **MS_HW_LUN** - Monitor Type: **MONITOR** - Monitor Category: **System**  
No CDM Class defined.  


Monitors a specific LUN, which are volumes stored on a remote disk array and that are exposed to the operating system of a server as a hard disk by the HBA card (host bus adapter, typically a fiber channel card).

Note: In most redundant systems, a LUN can be accessed through different paths. Hardware Sentry checks the multi-path I/O (MPIO), if configured, to identify and monitor the unique LUNs.

### Attributes (Parameters)

| Name | PATROL Name | Units | Default Thresholds | Description |
| --- | --- | --- | --- | --- |
| Available Path Count | AvailablePathCount | paths | None | Number of distinct paths available to the remote volume. Value set by lunColl. Type: Statistics - Default graph |
| Status | Status | 0 = OK 1 = Degraded 2 = Failed |  WARN if = 1 (Degraded)  ALARM if = 2 (Failed) | Availability of the remote volume. Value set by lunColl. Type: Availability - Default graph |
| Status Information | StatusInformation | None | None | Additional (textual) information about the current status of the LUN. Value set by lunColl. Type: Text |