date_published: 2026-11-09
date_modified: 2026-11-09
---

 [Back to the list of classes](km-reference.html)

## Hardware Power Supply

PATROL Class: **MS_HW_POWERSUPPLY** - Monitor Type: **MONITOR** - Monitor Category: **System**  
No CDM Class defined.  


Monitors a specific power supply. Power supply is a highly critical device of a computer that should never fail. Because of that, many vendors build servers with redundant power supplies. Monitoring power supplies allows the operators to be alerted when a power supply fails, or even in some cases when a power supply is overloaded.

### Attributes (Parameters)

| Name | PATROL Name | Units | Default Thresholds | Description |
| --- | --- | --- | --- | --- |
| Present | Present | 0 = Missing 1 = Present |  ALARM if = 0 (Missing) | Indicates whether the power supply is found or not. Value set by powerSupplyColl. Type: Availability |
| Status | Status | 0 = OK 1 = Degraded 2 = Failed |  WARN if = 1 (Degraded)  ALARM if = 2 (Failed) | Power supply status. Value set by powerSupplyColl. Type: Availability - Default graph |
| Status Information | StatusInformation | None | None | Additional (textual) information about the current status of the power supply. Value set by powerSupplyColl. Type: Text |
| Used Capacity | UsedCapacity | % |  WARN if ∈ [90 %, 99 %]  ALARM if ∈ [99 %, 100 %] | Percentage of the power supply power currently in use, if available. An alert is triggered when the power supply's maximum power output is reached. Value set by powerSupplyColl. Note: Alert thresholds are set automatically by Hardware Sentry which should not be customized or modified. Type: Statistics |