Hitachi Storage Pool

Home  Previous  Next

Attributes

Name

Description

Unit

Default Alert Conditions

Attribute Type

Consumed Capacity

Total size of the space actually allocated or reserved.

Terabytes (TB)

None

Statistics

Consumed Capacity Percentage

Percentage of the storage pool that is actually allocated or reserved.

Percentage (%)

Warning ≥ 80%

Alarm ≥ 90%

Statistics

Oversubscription Situation

This attribute reports an oversubscription situation, that is when:

 

1.The storage pool is configured for thin provisioning (“thin storage pool”)

 

2.the SubscribedCapacityPercentage parameter is greater than 100%, and

 

3.the ConsumedCapacityPercentage parameter is greater than 75%

 

Such situation is highly critical because the inability to allocate additional space to a volume when requested by the subscriber host will lead to catastrophic data loss and corruption.

{0= No; 1 = Yes}

Alarm = 1

Statistics

Subscribed Capacity

Total host visible capacity.

Terabytes (TB)

None

Statistics

Subscribed Capacity Percentage

Percentage of the storage pool that is subscribed.

 
Note: This parameter can exceed 100 % for thin provisioned storage pools.

Percentage (%)

Warning ≥ 80%

Alarm ≥ 90%

Statistics

Transfer Byte Rate

Count of data transferred per second.

Megabytes per second (MB/s)

None

Statistics