SEN_EVA_PORTSTATUS

Home  Previous  Next

Icon

SEN_EVA_portstatus_ok_32

Parameters

Name

Description

Unit

Default Alert Conditions

Type

AbnormalEOF

Number of abnormal EOF encountered on this port.

Errors

Warning ≥ 1

Statistics

BadCharactersReceived

Number of bad characters received by this port.

Characters

Warning ≥ 1

Statistics

BadCRC

Number of bad CRC encountered on this port.

Errors

Warning ≥ 1

Statistics

DiscardedFrames

Number of discarded frames by this port.

Frames

Warning ≥ 1

Statistics

LinkFailures

Number of link failures encountered by this port.

Failures

Warning ≥ 1

Statistics

LossOfSignal

Number of losses of signal encountered by this port.

Losses

Warning ≥ 1

Statistics

LossOfSynch

Number of losses of synchronization encountered on this port.

Losses

Warning ≥ 1

Statistics

ProtocolErrors

Number of protocol errors encountered on this port.

Errors

Warning ≥ 1

Statistics

Status*

Overall status of this port.

{0= Plugged; 1=Unplugged}

Warning = 1

Availability

* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in BPPM

InfoBox

Name

Description

PATROL ID

The device's PATROL internal identifier. This ID is used for PATROL event reporting etc.

ID

Port's ID.

Type

Port's type.

Menu Commands

Function

Description

Acknowledge Alerts and Reset

Resets the PortStatus parameters to zero.

Pause Monitoring

Pauses the monitoring of the selected object.

Resume Monitoring

Resumes the monitoring of the selected object.

Remove

Removes the selected object from the monitoring environment.