Unloading the KM from PATROL Console

Home  Previous  Next

Application classes are unloaded individually. This allows for a partial unloading of the KM to enable it to run as a reduced installation. Follow the steps below to unload the BEX KM completely or partially.

1.Remove the unwanted BEX KM application classes from the list of loaded application classes, as required. All BEX KM application classes start with BEX_.

With the PATROL Console for Unix:

From the PATROL Console main window choose Attributes > Application Classes...
Select a BEX KM application class to be removed and choose Edit > Delete.
Repeat for all classes to be removed.

With the PATROL Console for MS Windows:

From the PATROL Console tree view choose the KM tab and expand the folder Application Classes.
Right-click on a BEX KM application class to be removed and choose Delete.
Repeat for all classes to be removed.
2.Select File > Save Configuration to save the modified list of loaded application classes as the PATROL Console user preference.