10 Changes - Released 2019-01-08What's New
ID | Description |
---|---|
HC-995 | Add Support for Fujitsu ServerView Version 8 |
HC-993 | EMC Navisphere CLI: Add support for VNX systems with SPE enclosures |
HC-964 | Add support for Juniper Switches |
HC-937 | Add Support for Dell MD3000 (smcli) |
Changes and Improvements
ID | Description |
---|---|
HC-994 | Data Domain Storage Appliance (SNMP): Battery discharges should not be considered as alarming |
HC-991 | Dell Compellent: Add support for Dell REST API version 3 and higher |
HC-983 | IBM HMC - Include Additional Event Information (HMC v8+ only) |
HC-958 | Hitachi VSP G Series : Ethernet Ports are now discovered and monitored |
HC-942 | EMC VNX/Celerra/Clariion: Disabled ports trigger false alerts |
Fixed Issues
ID | Description |
---|---|
HC-1002 | Fujitsu ServerView: Added serial number and fixed incorrect temperature alert |
Hardware Connectors 13
4 Changes - Released 2018-11-16What's New
ID | Description |
---|---|
HC-981 | Add support of physical network interfaces for HP ProLiant Gen8 (and later) servers through iLO |
Changes and Improvements
ID | Description |
---|---|
HC-979 | Dell EqualLogic: Add support for Controllers |
Fixed Issues
ID | Description |
---|---|
HC-987 | Oracle/Sun Solaris - Environment (prtpicl): Temperature and Voltage parameters not properly collected. |
HC-986 | EMC Celerra/VNX Unified System (SSH): block storage may not be discovered |
Hardware Connectors 12
9 Changes - Released 2018-09-21What's New
ID | Description |
---|---|
HC-975 | Add support for Lenovo ThinkSystem SR630 rack-mount servers |
HC-970 | Add support for Cisco UCS S-Series |
HC-680 | Add support for IBM XIV Storage Systems through XCLI |
Changes and Improvements
ID | Description |
---|---|
HC-978 | EMC Isilon - Improve Storage Pool event descriptions |
HC-976 | HP Insight Management Agent - Drive Array: Improve disk controller's status when its battery is recharging |
Fixed Issues
ID | Description |
---|---|
HC-980 | EMC Navisphere CLI (Global User): Physical disks are not discovered |
HC-973 | EMC SMI-S Agent (ECOM) connector: missing instances due to duplicate DeviceID's |
HC-972 | NetApp Filer (SNMP): Physical disks may not be discovered |
HC-971 | Cisco UCS C-Series CIMC (SNMP): Enclosure status is inaccurate, connector applies to non C-series servers |
Hardware Connectors 11
7 Changes - Released 2018-07-18What's New
ID | Description |
---|---|
HC-864 | Add support for Nimble Storage Systems |
Changes and Improvements
ID | Description |
---|---|
HC-965 | Dell EMC VNX: Add support for latest version of navisseccli |
HC-960 | Linux Network: ip is now preferred over ifconfig in 2 separate connectors |
HC-951 | NetApp Filers: Disk Shelves are displayed as separate objects (requires ONTAP 9), System Electronics Monitoring, Part Numbers of Power Supplies |
Fixed Issues
ID | Description |
---|---|
HC-966 | Oracle/Sun Solaris - Environment (prtpicl): False alarms on disabled voltage, temperature, LED and fan sensors |
HC-962 | Fiber Alliance switches: Link Status and Bandwidth Utilization parameters not properly collected |
HC-961 | Dell EqualLogic: Status of physical disks not properly interpreted for newer versions of EqualLogic |
Hardware Connectors 10
5 Changes - Released 2018-05-30What's New
ID | Description |
---|---|
HC-956 | Add support for Hitachi VSP G Series through Storage Navigator SMI-S |
HC-955 | Linux - Network: Add support for interface name starting with enp, ens, eno and for systems where net-tools (ifconfig) is not installed |
Changes and Improvements
ID | Description |
---|---|
HC-953 | Dell Compellent: Serial Number and Service Tag added for controllers |
HC-952 | Oracle/Sun - ZFS Storage Appliance : SSH connections are serialized to avoid connection limit |
Fixed Issues
ID | Description |
---|---|
HC-946 | IBM AIX - Common: Connector not reporting network interfaces in "Dead" state |
Hardware Connectors 9
8 Changes - Released 2018-05-04What's New
ID | Description |
---|---|
HC-941 | Add the monitoring of power supplies for IBM Data Power |
HC-886 | Add support for Dell Compellent |
Changes and Improvements
ID | Description |
---|---|
HC-948 | HP Insight Management Agent - Server: Power supply may be reported as Unknown when unplugged or removed |
HC-943 | Improve performance of EMC VNX/Clariion/Celerra connectors |
Fixed Issues
ID | Description |
---|---|
HC-949 | NetApp: Physical disks not discovered or no alarms triggered for failed disks |
HC-947 | Dell iDRAC - Server: False alarms triggered on network cards |
HC-945 | IBM VIO Server: LinkSpeed displayed as 10 Mbits for 10-Gbit network interfaces |
HC-944 | Quantum Scalar i6000: False alarms generated on invalid voltage sensors |
Hardware Connectors 8
13 Changes - Released 2018-03-27What's New
ID | Description |
---|---|
HC-939 | EMC Navisphere - Always alert on removed disks |
HC-860 | EMC Data Domain: Added monitoring of battery status |
HC-836 | Add support for HP EVA SSSU on Linux |
HC-714 | Added: Support for EMC Celerra and EMC VNX Unified (Block and NAS credentials must be identical). Support for Global and LDAP users on EMC VNX/CLARiiON. RAID Group / Storage Pool Monitoring added. Components without a status will no longer be shown. |
HC-560 | Add support for Quanta Rack Mount Server Unit (a.k.a. Ericsson Hyperscale) |
Changes and Improvements
ID | Description |
---|---|
HC-938 | Dell iDRAC - Server connector: Improve network cards IDs to avoid false alarms and display names |
HC-865 | Removed support for Sun/Oracle ALOM monitoring (telnet protocol is no longer supported) |
HC-810 | Oracle X5 - /SYS/PWRBS sensor generating false alarms |
HC-601 | IBM DS (LSI) Disk Arrays (smcli): Improved discovery and identification of hardware components |
HC-596 | IBM HMC: Add refcode and actual time of the monitored events |
Fixed Issues
ID | Description |
---|---|
HC-935 | HP ProLiant: Extraneous memory modules are discovered |
HC-897 | SSSU Connector - Various fixes and improvements in the discovery |
HC-664 | Brocade SAN Switches (SNMP): Inaccurate values for traffic parameters caused by 32-bit counters overflow |
Hardware Connectors 7
6 Changes - Released 2018-02-16What's New
ID | Description |
---|---|
HC-708 | Add support for Synology DiskStation |
HC-401 | Add support for IBM FlashSystem 800 / 900 Series |
Changes and Improvements
ID | Description |
---|---|
HC-888 | HP ProLiant Servers (SNMP) - Serial and Model Numbers are properly reported |
Fixed Issues
ID | Description |
---|---|
HC-846 | "Hitachi HDS AMS/HUS - SNM2 CLI" connector may generate false alarms for Logical Disks |
HC-830 | Cisco UCS C-Series CIMC (SNMP): Empty slots discovered as physical disks |
HC-576 | EMC VNXe (uemcli): Unwanted disk instances, SSL certificate issues |
Hardware Connectors 6
37 Changes - Released 2017-12-22What's New
ID | Description |
---|---|
HC-819 | Add support for EMC VPLEX |
HC-681 | Add support for HP 3PAR Storage Systems |
HC-530 | Add support for EMC Unity Storage Systems based on the embedded SMI-S provider |
HC-508 | Add support for EMC Isilon ONEFS 8 OS |
HC-480 | Add support for F5 BIG-IP and Radware Load Balancers |
Changes and Improvements
ID | Description |
---|---|
HC-700 | EMC DataDomain: Disk Status incorrectly reported as 'Unknown' |
HC-647 | EMC Navisphere CLI: Add support for Linux, no longer requires administrator privileges |
HC-615 | EMC Isilon ONEFS 8: Storage pool capacity may be wrong |
HC-584 | Dell iDRAC - Storage: Improved Monitoring of Logical and Physical Disks |
HC-559 | Dell M1000E Chassis: Connections Serialized to Avoid CMC Saturation |
HC-469 | EMC DataDomain: More accurate labelling of the monitored objects |
HC-448 | Huawei RH2288H V3 Servers: Proper Labeling of Memory modules |
HC-444 | Fusion ioDrive: Add support for Windows |
HC-407 | Hitachi HNAS Systems: Add monitoring of System Drives and FC Ports |
HC-325 | Hitachi ComputeBlade 500: Add monitoring of temperature, fan, and voltage sensors |
HC-76 | On Windows, LUNs (MPIO Disks) needs to be monitored even if no FC ports are present |
Fixed Issues
ID | Description |
---|---|
HC-746 | Degraded Controller Status on Disk Controllers for Oracle SPARC T5,T7 Servers |
HC-731 | "NetApp Filer - SNMP Agent" connector generating false alarms |
HC-694 | Missing Network Interfaces under individual Blades for Brocade SAN Switch |
HC-627 | NetApp Filers (SNMP): Properly handle "mixed_raid_type" as the status of an aggregate |
HC-602 | Oracle/Sun ILOM (SNMP): The status of LEDs (notably on power supplies) did not trigger alerts |
HC-544 | Sun Iostat (Non-Sun Disks): NETAPP LUN Detected as Physical Disk |
HC-515 | EMC Isilon ONEFS: Physical disks' status L3 generating false alarms |
HC-514 | Cisco SAN Switches (SSH): No data collected for statistical parameters on FC ports |
HC-507 | HP BladeSystem (SSH): The connector does not activate on newest firmware |
HC-506 | Pure Storage: Physical disks and other components not properly attached to the enclosure |
HC-501 | HP Insight Management (SNMP): Temperature thresholds not set correctly |
HC-489 | VMware ESXi: Port Speed and Duplex state not collected |
HC-475 | IBM VIOS: Errors related to ioscli in System Output Window |
HC-460 | Cisco UCS B200: Physical Network Interfaces showing duplicate MAC addresses |
HC-450 | EMC PowerPath: The connector did not activate when using sudo |
HC-417 | IBM VIO Server: No collected value for traffic and LinkStatus on virtual ports in SEA Virtual Adapters |
HC-394 | Quantum DXi (SSH): False alerts on physical disks, and various timeout error messages |
HC-377 | EMC Isilon: A logical disk with the name of "Drives:" triggers false alerts |
HC-336 | Oracle Netra SPARC T4-1: No CPUs discovered |
HC-280 | EMC VNX, VNXe: uemcli and Navisphere CLI connectors both activate, "unbound state" not recognized for disks |
HC-27 | IBM BladeCenter: Fan energy saving is not taken into account and triggers false alerts |