SEN_EMC_FCPORT

Home  Previous  Next

Icon

sen_emc_fcport_ok_32

Parameters

Name

Description

Units

Default Alert Conditions

Attribute Type

Present

Indicates whether the device is present or not since the last collect.

{0 = No; 1 = Yes}

Warning = 0

Availability

Status*

Status of the device.

{0=OK; 1 = Degraded; 2 = Failed}

Warning = 1
Alarm = 2

Availability

StatusInformation

Detailed information about the Fiber port status.

n/a

n/a

n/a

TransferByteRate*

Count of data transferred per second.

Note: This attribute is not available on Symmetrix Vmax devices.

Megabytes per second (MB/s)

None

Statistics

Volumes

List of volumes that are accessible through this port.

n/a

None

--

*Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.

InfoBox

Name

Description

PATROL ID

The PATROL internal identifier.

Role

Indicates the role of the port (Front-end;Back-end;Not restricted, Unknown, N/A).

Speed

Indicates the port connection speed (Negotiated speed).

Type

Indicates the type of the port (Ethernet, IB;FC, FDDI, ATM, Token Ring, Frame Relay, Infrared, BlueTooth, Wireless LAN, Other, Unknown).

WWN

WWN address of the Fiber Port on the SAN.

MetaTokenID

Identifier of the instance. This identifier is required to ensure the instance is properly interpreted by BMC TrueSight Operations Management.

CI_ID

Identifier of the configuration item.

         

Menu Commands

Function

Description

Fiber Port Activity

Generates a report on Fiber port activity.

Pause Monitoring

Pauses the monitoring of the selected object.

Resume Monitoring

Resumes the monitoring of the selected object.

Remove

Removes the selected object from the monitoring environment.