Description
This connector discovers the status of an HPE Proliant Gen 9 system using iLO 4, as well as the various environment sensors (temperatures, fans, power supplies, etc.). Requires iLO 4.
Target
Typical platform: HP iLO Gen 9 REST
Operating system: Out-of-Band
Prerequisites
Requires KM Version: 10.3.00 or greater
Leverages:
Technology and protocols: HTTP/REST
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The HP iLO Gen 9 (REST) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The KM is in version 10.3.00 or greater
- The HTTP Request below to the managed host succeeds:
- GET
/redfish/v1/ - Request Header:
EmbeddedFile(1) - The response body contains:
iLO 4(regex)
- GET
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Enclosure (MS_HW_ENCLOSURE) |
|
|
| Disk Controller (MS_HW_DISKCONTROLLER) |
|
|
| Battery (MS_HW_BATTERY) |
|
|
| Processor (MS_HW_CPU) |
|
|
| Fan (MS_HW_FAN) |
|
|
| Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
| Memory Module (MS_HW_MEMORY) |
|
|
| Network Card, FC Port (MS_HW_NETWORK) |
|
|
| Physical Disk (MS_HW_PHYSICALDISK) |
|
|
| Power Supply (MS_HW_POWERSUPPLY) |
|
|
| Temperature Sensor (MS_HW_TEMPERATURE) |
|
|