Release Notes
This page lists the new features, improvements, changes and bug fixes in each version of Hardware Connector Library.
Hardware Connectors 23
3 Changes - Released 2021-03-18
What's New
| ID |
Description |
| HC-1369 |
Added support for HPE ProLiant Gen 9 and 10 via iLO REST |
| HC-1049 |
Added support for HPE Synergy chassis |
| HC-634 |
Added support for Cisco UCS blade components through Cisco UCS Manager SNMP agent |
Hardware Connectors 22
11 Changes - Released 2021-02-04
What's New
| ID |
Description |
| HC-1084 |
Standardized detailed information display for all monitored devices |
Changes and Improvements
| ID |
Description |
| HC-1364 |
Dell MX7000: Monitoring of Endurance Remaining for SSD |
| HC-1362 |
NetApp E-Series: Monitoring of Endurance Remaining for SSD |
| HC-1359 |
Cisco UCS (CIMC): "Inoperable" status is now reported as Alarm instead of Warning |
| HC-1355 |
EMC VPLEX: Added support for new authentication methods |
| HC-1347 |
EMC SMI-S Agent (ECOM): Created a separate device for each disk array in TrueSight |
Fixed Issues
| ID |
Description |
| HC-1372 |
HP 3PAR Disk Array: Ethernet Ports' Status and StatusInformation may be wrongly translated |
| HC-1368 |
Isilon battery status is flagged incorrectly as alert for Good-Test and Testing-Good |
| HC-1363 |
Dell EqualLogic PS Series: Non-existing NVRAM batteries may be discovered but reported as missing |
| HC-1361 |
HP Integrated Lights-Out Management Card - Network : No data for LinkStatus |
| HC-1352 |
Pure Storage FA Series (REST) fails when the API version is lower than 1.3 |
Hardware Connectors 21
5 Changes - Released 2020-10-19
What's New
| ID |
Description |
| HC-1344 |
Add support for Pure Storage REST |
| HC-1077 |
Add support for NetApp SolidFire |
Changes and Improvements
| ID |
Description |
| HC-1348 |
Hitachi Storage Command Suite SMI-S Agent: Create a separate device for each disk array in TrueSight |
| HC-1330 |
Dell MX Chassis and Blades (REST): Improved blade and chassis naming and ID |
| HC-1074 |
Dell iDRAC9 (REST): Add support for rack mount servers |
Hardware Connectors 20
12 Changes - Released 2020-09-17
What's New
| ID |
Description |
| HC-1048 |
Add support for Dell EMC XtremIO |
Changes and Improvements
| ID |
Description |
| HC-1336 |
Isilon Voltage thresholds are too aggressive for connector MS_HW_EMCIsilonREST.hdfs |
| HC-1334 |
EMC Navisphere CLI: Add Additional Statuses |
| HC-1332 |
ESXi version check needs to be adjusted for ESX7 for several connectors |
| HC-1331 |
VMware ESXi: Add the monitoring of battery |
| HC-1082 |
Dell Compellent Storage Manager: Create Separate Devices in Truesight |
| HC-1068 |
EMC Isilon 8 (SSH): Add Cluster Serial Number |
| HC-977 |
Cisco UCS C-Series: Improved identification of memory modules and physical disks |
Fixed Issues
| ID |
Description |
| HC-1339 |
NetApp E-Series: Connector doesn't activate for all systems |
| HC-1338 |
Isilon battery status is flagged incorrectly as alert for Good-Testing |
| HC-1335 |
HP Insight Management Agent-Drive Array: Battery is reported as missing instead of having a failed status when its capacitor is failed |
| HC-1062 |
Dell Compellent: Fans and Power Supplies may not be discovered with latest Storage Center |
Hardware Connectors 19
10 Changes - Released 2020-03-12
Changes and Improvements
| ID |
Description |
| HC-1064 |
EMC Celerra: Alarm not generated on a faulted component |
| HC-1063 |
Dell EqualLogic PS Series : Report the service tag number of enclosures |
| HC-1054 |
HP BladeSystem: Activate Power Consumption and Temperature parameters only when its value is available. |
| HC-1053 |
Cisco UCS C-Series CIMC (SNMP): Add power consumption parameter |
| HC-1052 |
VMware ESXi: Deactivate temperature status parameter when temperature reading and sensors are available |
| HC-1051 |
Lenovo IMM: Activate Power Consumption parameter only when its value is available |
| HC-1050 |
Lenovo ThinkSystem: Activate Power Consumption parameter only when its value is available |
Fixed Issues
| ID |
Description |
| HC-1060 |
Cisco UCS C-Series CIMC (SNMP): removed devices may still be discovered |
| HC-1056 |
Dell MX7000 REST: Connector never activates |
| HC-1055 |
Dell iDRAC REST: Connector never activates |
Hardware Connectors 18
8 Changes - Released 2019-12-23
What's New
| ID |
Description |
| HC-1029 |
Add support for monitoring Dell servers via their iDRAC using REST |
| HC-1014 |
Add Support for SuperMicro systems |
Changes and Improvements
| ID |
Description |
| HC-1045 |
HP SSSU - Add Support for EVA HSV3xx controller enclosures. Fixed Physical Disk Sizes. |
| HC-1044 |
Brocade SAN Switch SMI Agent - Create separate devices for each physical switch in TrueSight |
| HC-1042 |
VMware ESXi 5 LUN (SSH): On Nimble, take into account LUNs having "eui" as prefix in their Device name |
| HC-1041 |
Data Domain Storage Appliance (SNMP): Battery status may be wrongly reported |
| HC-1031 |
Support of Dell MX7000 Chassis (REST) |
Fixed Issues
| ID |
Description |
| HC-1034 |
IBM AIX: LinkSpeed displays 10 Mb/s for 10-Gb/s network interfaces |
Hardware Connectors 17
5 Changes - Released 2019-09-24
What's New
| ID |
Description |
| HC-1025 |
Add support for Dell MX7000 Chassis (SSH) |
Changes and Improvements
| ID |
Description |
| HC-1039 |
EMC uemcli (VNXe) : Force serialization of the different uemcli commands |
| HC-1037 |
EMC Isilon: Change physical disk "Replace" status to alarm |
| HC-1030 |
IBM VIO Server Connector: Data collection for network interfaces takes too long or times out |
Fixed Issues
| ID |
Description |
| HC-1038 |
Dell Compellent: Connector does not activate |
Hardware Connectors 16
5 Changes - Released 2019-06-25
What's New
| ID |
Description |
| HC-430 |
Add support for NetApp E-Series Storage Systems |
Changes and Improvements
| ID |
Description |
| HC-1023 |
EMC DataDomain - Add Numeric Percentage for Battery Charge |
| HC-1020 |
NetApp: Add support for monitoring 7-mode systems via ONTAP API |
| HC-1018 |
EMC Navisphere - Alert on removed devices - Add controller modules part numbers on some systems |
Fixed Issues
| ID |
Description |
| HC-1024 |
Lenovo: Incorrect Voltage value |
Hardware Connectors 15
10 Changes - Released 2019-03-13
What's New
| ID |
Description |
| HC-1016 |
Add support for older VPLEX systems (5.5 or earlier) |
| HC-1006 |
Add support for Dell EMC Isilon through SNMP |
| HC-1005 |
Add support for Dell EMC Isilon through REST API |
| HC-854 |
Add support for NetApp through REST API |
Changes and Improvements
| ID |
Description |
| HC-1011 |
IBM xSeries IMM - Add support for older systems |
| HC-990 |
MS_HW_IBMVIOS.hdf: Add the monitoring of all FC cards |
Fixed Issues
| ID |
Description |
| HC-1015 |
EMC Isilon SSH - Prevent false logical disk instances creating alerts |
| HC-1012 |
EMC Isilon 8 (SSH) : Battery Status is not interpreted properly |
| HC-1009 |
Dell MD3000 - IBM SMcli connector would activate superfluously |
| HC-1007 |
EMC Navisphere CLI - "Resume Faulted" is not properly reported |
Hardware Connectors 14
10 Changes - Released 2019-01-08
What's New
| ID |
Description |
| HC-995 |
Add Support for Fujitsu ServerView Version 8 |
| HC-964 |
Add support for Juniper Switches |
| HC-937 |
Add Support for Dell MD3000 (smcli) |
Changes and Improvements
| ID |
Description |
| HC-994 |
Data Domain Storage Appliance (SNMP): Battery discharges should not be considered as alarming |
| HC-993 |
EMC Navisphere CLI: Add support for VNX systems with SPE enclosures |
| HC-991 |
Dell Compellent: Add support for Dell REST API version 3 and higher |
| HC-983 |
IBM HMC - Include Additional Event Information (HMC v8+ only) |
| HC-958 |
Hitachi VSP G Series : Ethernet Ports are now discovered and monitored |
| HC-942 |
EMC VNX/Celerra/Clariion: Disabled ports trigger false alerts |
Fixed Issues
| ID |
Description |
| HC-1002 |
Fujitsu ServerView: Added serial number and fixed incorrect temperature alert |
Hardware Connectors 13
4 Changes - Released 2018-11-16
Changes and Improvements
| ID |
Description |
| HC-981 |
Add support of physical network interfaces for HP ProLiant Gen8 (and later) servers through iLO |
| HC-979 |
Dell EqualLogic: Add support for Controllers |
Fixed Issues
| ID |
Description |
| HC-987 |
Oracle/Sun Solaris - Environment (prtpicl): Temperature and Voltage parameters not properly collected. |
| HC-986 |
EMC Celerra/VNX Unified System (SSH): block storage may not be discovered |
Hardware Connectors 12
9 Changes - Released 2018-09-21
What's New
| ID |
Description |
| HC-975 |
Add support for Lenovo ThinkSystem SR630 rack-mount servers |
| HC-970 |
Add support for Cisco UCS S-Series |
| HC-680 |
Add support for IBM XIV Storage Systems through XCLI |
Changes and Improvements
| ID |
Description |
| HC-978 |
EMC Isilon - Improve Storage Pool event descriptions |
| HC-976 |
HP Insight Management Agent - Drive Array: Improve disk controller's status when its battery is recharging |
Fixed Issues
| ID |
Description |
| HC-980 |
EMC Navisphere CLI (Global User): Physical disks are not discovered |
| HC-973 |
EMC SMI-S Agent (ECOM) connector: missing instances due to duplicate DeviceID's |
| HC-972 |
NetApp Filer (SNMP): Physical disks may not be discovered |
| HC-971 |
Cisco UCS C-Series CIMC (SNMP): Enclosure status is inaccurate, connector applies to non C-series servers |
Hardware Connectors 11
7 Changes - Released 2018-07-18
What's New
| ID |
Description |
| HC-864 |
Add support for Nimble Storage Systems |
Changes and Improvements
| ID |
Description |
| HC-965 |
Dell EMC VNX: Add support for latest version of navisseccli |
| HC-960 |
Linux Network: ip is now preferred over ifconfig in 2 separate connectors |
| HC-951 |
NetApp Filers: Disk Shelves are displayed as separate objects (requires ONTAP 9), System Electronics Monitoring, Part Numbers of Power Supplies |
Fixed Issues
| ID |
Description |
| HC-966 |
Oracle/Sun Solaris - Environment (prtpicl): False alarms on disabled voltage, temperature, LED and fan sensors |
| HC-962 |
Fiber Alliance switches: Link Status and Bandwidth Utilization parameters not properly collected |
| HC-961 |
Dell EqualLogic: Status of physical disks not properly interpreted for newer versions of EqualLogic |
Hardware Connectors 10
5 Changes - Released 2018-05-30
What's New
| ID |
Description |
| HC-956 |
Add support for Hitachi VSP G Series through Storage Navigator SMI-S |
Changes and Improvements
| ID |
Description |
| HC-955 |
Linux - Network: Add support for interface name starting with enp, ens, eno and for systems where net-tools (ifconfig) is not installed |
| HC-953 |
Dell Compellent: Serial Number and Service Tag added for controllers |
| HC-952 |
Oracle/Sun - ZFS Storage Appliance : SSH connections are serialized to avoid connection limit |
Fixed Issues
| ID |
Description |
| HC-946 |
IBM AIX - Common: Connector not reporting network interfaces in "Dead" state |
Hardware Connectors 9
8 Changes - Released 2018-05-04
What's New
| ID |
Description |
| HC-886 |
Add support for Dell Compellent |
Changes and Improvements
| ID |
Description |
| HC-948 |
HP Insight Management Agent - Server: Power supply may be reported as Unknown when unplugged or removed |
| HC-943 |
Improve performance of EMC VNX/Clariion/Celerra connectors |
| HC-941 |
Add the monitoring of power supplies for IBM Data Power |
Fixed Issues
| ID |
Description |
| HC-949 |
NetApp: Physical disks not discovered or no alarms triggered for failed disks |
| HC-947 |
Dell iDRAC - Server: False alarms triggered on network cards |
| HC-945 |
IBM VIO Server: LinkSpeed displayed as 10 Mbits for 10-Gbit network interfaces |
| HC-944 |
Quantum Scalar i6000: False alarms generated on invalid voltage sensors |
Hardware Connectors 8
13 Changes - Released 2018-03-27
What's New
| ID |
Description |
| HC-836 |
Add support for HP EVA SSSU on Linux |
| HC-560 |
Add support for Quanta Rack Mount Server Unit (a.k.a. Ericsson Hyperscale) |
Changes and Improvements
| ID |
Description |
| HC-939 |
EMC Navisphere - Always alert on removed disks |
| HC-938 |
Dell iDRAC - Server connector: Improve network cards IDs to avoid false alarms and display names |
| HC-865 |
Removed support for Sun/Oracle ALOM monitoring (telnet protocol is no longer supported) |
| HC-860 |
EMC Data Domain: Added monitoring of battery status |
| HC-810 |
Oracle X5 - /SYS/PWRBS sensor generating false alarms |
| HC-714 |
Added: Support for EMC Celerra and EMC VNX Unified (Block and NAS credentials must be identical). Support for Global and LDAP users on EMC VNX/CLARiiON. RAID Group / Storage Pool Monitoring added. Components without a status will no longer be shown. |
| HC-601 |
IBM DS (LSI) Disk Arrays (smcli): Improved discovery and identification of hardware components |
| HC-596 |
IBM HMC: Add refcode and actual time of the monitored events |
Fixed Issues
| ID |
Description |
| HC-935 |
HP ProLiant: Extraneous memory modules are discovered |
| HC-897 |
SSSU Connector - Various fixes and improvements in the discovery |
| HC-664 |
Brocade SAN Switches (SNMP): Inaccurate values for traffic parameters caused by 32-bit counters overflow |
Hardware Connectors 7
6 Changes - Released 2018-02-16
What's New
| ID |
Description |
| HC-708 |
Add support for Synology DiskStation |
| HC-401 |
Add support for IBM FlashSystem 800 / 900 Series |
Changes and Improvements
| ID |
Description |
| HC-888 |
HP ProLiant Servers (SNMP) - Serial and Model Numbers are properly reported |
Fixed Issues
| ID |
Description |
| HC-846 |
"Hitachi HDS AMS/HUS - SNM2 CLI" connector may generate false alarms for Logical Disks |
| HC-830 |
Cisco UCS C-Series CIMC (SNMP): Empty slots discovered as physical disks |
| HC-576 |
EMC VNXe (uemcli): Unwanted disk instances, SSL certificate issues |
Hardware Connectors 6
37 Changes - Released 2017-12-22
What's New
| ID |
Description |
| HC-819 |
Add support for EMC VPLEX |
| HC-681 |
Add support for HP 3PAR Storage Systems |
| HC-530 |
Add support for EMC Unity Storage Systems based on the embedded SMI-S provider |
| HC-508 |
Add support for EMC Isilon ONEFS 8 OS |
| HC-480 |
Add support for F5 BIG-IP and Radware Load Balancers |
Changes and Improvements
| ID |
Description |
| HC-700 |
EMC DataDomain: Disk Status incorrectly reported as 'Unknown' |
| HC-647 |
EMC Navisphere CLI: Add support for Linux, no longer requires administrator privileges |
| HC-615 |
EMC Isilon ONEFS 8: Storage pool capacity may be wrong |
| HC-584 |
Dell iDRAC - Storage: Improved Monitoring of Logical and Physical Disks |
| HC-559 |
Dell M1000E Chassis: Connections Serialized to Avoid CMC Saturation |
| HC-469 |
EMC DataDomain: More accurate labelling of the monitored objects |
| HC-448 |
Huawei RH2288H V3 Servers: Proper Labeling of Memory modules |
| HC-444 |
Fusion ioDrive: Add support for Windows |
| HC-407 |
Hitachi HNAS Systems: Add monitoring of System Drives and FC Ports |
| HC-325 |
Hitachi ComputeBlade 500: Add monitoring of temperature, fan, and voltage sensors |
| HC-76 |
On Windows, LUNs (MPIO Disks) needs to be monitored even if no FC ports are present |
Fixed Issues
| ID |
Description |
| HC-746 |
Degraded Controller Status on Disk Controllers for Oracle SPARC T5,T7 Servers |
| HC-731 |
"NetApp Filer - SNMP Agent" connector generating false alarms |
| HC-694 |
Missing Network Interfaces under individual Blades for Brocade SAN Switch |
| HC-627 |
NetApp Filers (SNMP): Properly handle "mixed_raid_type" as the status of an aggregate |
| HC-602 |
Oracle/Sun ILOM (SNMP): The status of LEDs (notably on power supplies) did not trigger alerts |
| HC-544 |
Sun Iostat (Non-Sun Disks): NETAPP LUN Detected as Physical Disk |
| HC-515 |
EMC Isilon ONEFS: Physical disks' status L3 generating false alarms |
| HC-514 |
Cisco SAN Switches (SSH): No data collected for statistical parameters on FC ports |
| HC-507 |
HP BladeSystem (SSH): The connector does not activate on newest firmware |
| HC-506 |
Pure Storage: Physical disks and other components not properly attached to the enclosure |
| HC-501 |
HP Insight Management (SNMP): Temperature thresholds not set correctly |
| HC-489 |
VMware ESXi: Port Speed and Duplex state not collected |
| HC-475 |
IBM VIOS: Errors related to ioscli in System Output Window |
| HC-460 |
Cisco UCS B200: Physical Network Interfaces showing duplicate MAC addresses |
| HC-450 |
EMC PowerPath: The connector did not activate when using sudo |
| HC-417 |
IBM VIO Server: No collected value for traffic and LinkStatus on virtual ports in SEA Virtual Adapters |
| HC-394 |
Quantum DXi (SSH): False alerts on physical disks, and various timeout error messages |
| HC-377 |
EMC Isilon: A logical disk with the name of "Drives:" triggers false alerts |
| HC-336 |
Oracle Netra SPARC T4-1: No CPUs discovered |
| HC-280 |
EMC VNX, VNXe: uemcli and Navisphere CLI connectors both activate, "unbound state" not recognized for disks |
| HC-27 |
IBM BladeCenter: Fan energy saving is not taken into account and triggers false alerts |
Keywords:
hardware hdf patrol connectors
Search Results for {{siteSearch | truncate:'50'}}
{{resultArray.length}}
{{result.body | truncate:'400'}}
No results.