Back to the list of connectors
NetApp SolidFire (REST)
Connector file name: MS_HW_NetAppSolidFireREST.hdf
Description
This connector discovers and collects hardware health for NetApp SolidFire Storage Systems and communicates directly with the NetApp SolidFire System.
Target
Typical platform: NetApp SolidFire
Operating system: Storage System
Prerequisites
Leverages: SolidFire API
Technology and protocols: HTTP/REST
This connector is not available for the local host (it is applicable to remote hosts only).
Connector Activation Criteria
The NetApp SolidFire (REST) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- The HTTP Request below to the managed host succeeds:
- POST
/json-rpc/9.0 - Request Header:
Content-Type:text/plain - Request Body:
{"method" : "GetClusterInfo", "id" : "Detection" } - The response body contains:
{"id":"Detection"(regex)
- POST
Monitors
| Object Type | Discovered Properties | Collected Parameters |
|---|---|---|
| Enclosure (MS_HW_ENCLOSURE) |
|
|
| Disk Controller (MS_HW_DISKCONTROLLER) |
|
|
| Processor (MS_HW_CPU) |
|
|
| Fan (MS_HW_FAN) |
|
|
| Logical Disk, RAID (MS_HW_LOGICALDISK) |
|
|
| Memory Module (MS_HW_MEMORY) |
|
|
| Network Card, FC Port (MS_HW_NETWORK) |
|
|
| Physical Disk (MS_HW_PHYSICALDISK) |
|
|
| Power Supply (MS_HW_POWERSUPPLY) |
|
|
| Temperature Sensor (MS_HW_TEMPERATURE) |
|
|
| Voltage Sensor (MS_HW_VOLTAGE) |
|
|
Keywords:
hardware hdf patrol connectors
hardware hdf patrol connectors