Total size of the space actually allocated or reserved.
Terabytes (TB)
None
Statistics
ConsumedCapacityPercentage
Percentage of the storage pool that is actually allocated or reserved.
Percentage (%)
Warning ≥ 80%
Alarm ≥ 90%
Statistics
OversubscriptionSituation*
This parameter reports an oversubscription situation, that is when:
1.The storage pool is configured for thin provisioning (“thin storage pool”)
2.the SubscribedCapacityPercentage parameter is greater than 100%, and
3.the ConsumedCapacityPercentage parameter is greater than 75%
Such situation is highly critical because the inability to allocate additional space to a volume when requested by the subscriber host will lead to catastrophic data loss and corruption.
{0 = No ; 1 = Yes}
Alarm = 1
Statistics
SubscribedCapacity
Total host visible capacity.
Terabytes (TB)
None
Statistics
SubscribedCapacityPercentage
Percentage of the storage pool that is subscribed.
Note: This parameter can exceed 100 % for thin provisioned storage pools.
Percentage (%)
Warning ≥ 80%
Alarm ≥ 90%
Statistics
TransferByteRate*
Total bytes transferred per second (sent and received).
Megbaytes per second (MB/s)
None
Statistics
* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.
InfoBox
Name
Description
PATROL ID
The device's PATROL internal identifier.
Capacity
Number of bytes available in the storage pool (in TB).