Back to the list of classes

HP 3PAR Ethernet Port

PATROL Class: SEN_HP3P_ETHERNETPORT - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a specific Ethernet port.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Link Speed LinkSpeed Gb/s None

Negotiated or configured link speed (i.e. available bandwidth).

Type: Availability - Spikes expected

Present Present 0 = No
1 = Yes

 ALARM
if = 0 (No)

Indicates whether the device is still present or not since the last discovery. This parameter is updated at each collect.

Type: Availability - Spikes expected

Received Byte Rate ReceivedByteRate MB/s None

Bytes received per second.

Type: Statistics - Spikes expected

Received Response Time ReceivedResponseTime ms

 WARN
if ≥ 20 ms, 5 times in a row

Average response time for write operations.

Type: Response Time - Spikes expected

Response Time ResponseTime ms

 WARN
if ≥ 20 ms, 5 times in a row

Average response time for all operations.

Type: Response Time - Spikes expected - Default graph

Sent Byte Rate SentByteRate MB/s None

Bytes sent per second.

Type: Statistics - Spikes expected

Sent Response Time SentResponseTime ms

 WARN
if ≥ 20 ms, 5 times in a row

Average response time for sent operations.

Type: Response Time - Spikes expected

Status Status 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Status of the port.

Type: Availability - Spikes expected

Status Information StatusInformation None None

Detailed information about the port status.

Type: Text

Transfer Byte Rate TransferByteRate MB/s None

Total bytes transferred per second (sent and received).

Type: Statistics - Spikes expected - Default graph

Infoboxes (PATROL Console Only)

Name Description
PATROL ID The PATROL internal identifier.
Type Type of the port.
Full Duplex Indicates whether the port is operating in full duplex mode or not.
iSCSI IP Address IP address of the iSCSI or RCIP port.
MAC MAC address of the port.
Max Speed The maximum port speed in bits per second.
Purpose Purpose of the port (BackEndOnly | FrontEndOnly | NotRestricted | Unknown).
Menu Command Description
Ethernet Port Activity... Enables you to generate a report on the Ethernet port activity.
Acknowledge Status Alert Enables you to clear the alert on the Status parameter.
Pause Monitoring Pauses the monitoring of the selected object.
Resume Monitoring Resumes the monitoring of the selected object.
Remove Removes the selected object from the monitoring environment.
Keywords: