Back to the list of classes

HP 3PAR Storage System

PATROL Class: SEN_HP3P_STORAGESYSTEM - Monitor Type: MONITOR - Monitor Category: System
CDM Class: BMC_ComputerSystem -- Instances of this monitor will be represented as devices in TrueSight Operations Management

Monitors HP 3PAR storage systems.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Collection Status CollectionStatus 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Status of the collection.

Type: Collection Status - Spikes expected

Collection Status Information CollectionStatusInformation None None

Detailed information about the collection status. Errors encountered by Storage System will be reported in this parameter.

Type: Text

Operation Rate OperationRate operations/s None

Total number of operations per second.

Type: Statistics - Spikes expected

Port Count PortCount ports None

Number of ports in the storage system.

Type: Statistics

Power Consumption PowerConsumption Watts None

Power consumed by the storage system.

Type: Statistics

Present Present 0 = No
1 = Yes

 ALARM
if = 0 (No)

Indicates whether the device is still present or not since the last discovery. This parameter is updated at each collect.

Type: Availability - Spikes expected

Read Operation Rate ReadOperationRate operations/s None

Number of read operations per second.

Type: Statistics - Spikes expected

Received Byte Rate ReceivedByteRate MB/s None

Bytes received per second.

Type: Statistics - Spikes expected

Received Response Time ReceivedResponseTime ms

 WARN
if ∈ [30 ms, 100 ms], 2 times in a row

 ALARM
if ≥ 100 ms, 2 times in a row

Average response time for write operations.

Type: Response Time - Spikes expected

Response Time ResponseTime ms

 WARN
if ∈ [30 ms, 100 ms], 2 times in a row

 ALARM
if ≥ 100 ms, 2 times in a row

Average response time for all operations.

Type: Response Time - Spikes expected

Sent Byte Rate SentByteRate MB/s None

Bytes sent per second.

Type: Statistics - Spikes expected

Sent Response Time SentResponseTime ms

 WARN
if ∈ [30 ms, 100 ms], 2 times in a row

 ALARM
if ≥ 100 ms, 2 times in a row

Average response time for write operations.

Type: Response Time - Spikes expected

Status Status 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Status of the storage system.

Type: Availability - Spikes expected

Status Information StatusInformation None None

Detailed information about the storage system status.

Type: Text

Transfer Byte Rate TransferByteRate MB/s None

Total bytes transferred per second (sent and received).

Type:  KPI - Statistics - Spikes expected - Default graph

Write Operation Rate WriteOperationRate operations/s None

Number of write operations per second.

Type: Statistics - Spikes expected

Infoboxes (PATROL Console Only)

Name Description
PATROL ID The PATROL internal identifier.
Vendor Hardware vendor identifier.
Model Model of the storage system.
StoreServ Version Software version of the storage system.
Serial Number Serial number of the storage system.
WWN World Wide Name of the storage system.
IPv4 Address IPv4 address of the storage system.
IPv6 Address IPv6 address of the storage system.
FQDN Fully qualified domain name of the storage system.
MetaEntityType System model, updated upon each discovery cycle (typically: Storage.HP-3PAR).
Menu Command Description
Reporting > Storage System Activity... Enables you to generate a report on the storage system activity.
Reporting > Nodes Activity... Enables you to generate a report on the nodes activity.
Reporting > FC Ports Activity... Enables you to generate a report on the FC ports activity.
Reporting > Ethernet Ports Activity... Enables you to generate a report on the Ethernet ports activity.
Reporting > SAS Ports Activity... Enables you to generate a report on the SAS ports activity.
Reporting > Storage Pools Activity... Enables you to generate a report on the storage pools activity.
Reporting > Volumes Activity... Enables you to generate a report on the volumes activity.
Reporting > Physical Disks Activity... Enables you to generate a report on the physical disks activity.
Reporting > Virtual Volumes Owning Controller Table Enables you to generate a report to identify which controllers own which virtual volumes.
Reporting > Virtual Volumes Mapping Table... Enables you to generate a report listing mapped and unmapped virtual volumes.
Edit Connection Settings Enables you to edit the connection settings of the selected HP 3PAR storage system.
Search WWN/IQN... Enables you to find any component based on its complete or partial World Wide Name or IQN.
Discovery Interval... Enables you to customize the discovery cycle. By default, discovery is performed every hour.
Polling Interval... Enables you to customize the polling cycle. By default, polling is performed every 2 minutes.
Disable Volumes Monitoring... Disables the monitoring of all the volumes of a system.
Pause Monitoring Pauses the monitoring of the selected object.
Resume Monitoring Resumes the monitoring of the selected object.
Remove Removes the selected object from the monitoring environment.
Refresh Parameters Refreshes all parameters of the application class.
Keywords:
hp3par km patrol