SEN_NAP_7_FC_PORT

Home  Previous  Next

Icon

sen_nap_fc_port_ok_32

Parameters

Name

Description

Unit

Default Alert Conditions

Attribute Type

BandwidthUtilization

Percentage used of the available bandwidth.

Percentage (%)

None

Statistics

ConnectedInitiatorsCount

Total number of initiators (hosts) connected to this port (target adapter).

Initiators

None

Statistics

CRCErrorRate

CRC errors per second.

Errors/s

None

Statistics

DiscardedFrameRate

Number of frames discarded per second.

Frames/s

None

Statistics

FCPProtocolErrorRate

FCP protocol errors per second.

Errors/s

None

Statistics

InboundBandwidthUtilization

Percentage of inbound bandwidth used on the FC link (received bytes).

Percentage (%)

None

Statistics

LinkSpeed

Actual speed of the FC port.

Gigabits per second (Gb/s)

None

Statistics

LinkStatus

Indicates whether the link is up or down.

{0 = Plugged; 1 = Unplugged}

1 = Warning

Availability

OperationRate*

Total number of operations per second.

Operations/s

None

Statistics

OtherOperationRate

Total number of other operations per second.

Operations/s

None

Statistics

OutboundBandwidthUtilization

Percentage of outband bandwidth used on the FC link (sent bytes).

Percentage (%)

None

Statistics

Present

Indicates whether the device is still present or not since the last collect. This parameter is updated at each collect.

{0 = No; 1 = Yes}

0 = Alarm

Availability

ReadOperationRate

Number of operation read per second.

Operations/s

None

Statistics

ReceivedByteRate

Bytes received per second.

Megabytes per second (MB/s)

None

Statistics

SentByteRate

Bytes sent per second.

Megabytes per second (MB/s)

None

Statistics

Status

Status of the FC port.

{0 = OK; 1 = Degraded; 2 = Failed}

1 = Warning

2 = Alarm

Availability

StatusInformation

Detailed information about the adapter status.

n/a

None

--

TransferByteRate*

Total bytes transferred per second (sent and received).

Megabytes per second (MB/s)

None

Statistics

WriteOperationRate

Number of write operations per second.

Operations/s

None

Statistics

* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.

InfoBox

Name

Description

PATROL ID

Unique identifier of the object in the PATROL console.

WWNN

FCP World Wide Node Name (WWNN) of the adapter.

WWPN

FCP World Wide Port Name (WWPN) of the adapter.

Type

Type of the adapter.

Possible values: "physical", "local", "standby", "partner".

Configured Speed

Speed configured for this adapter.
Possible values: "auto", "1 Gb/s", "2 Gb/s", "4 Gb/s", "8 Gb/s", "10 Gb/s".

StandBy

Indicates whether the adapter is on standby.

Speed Capabilities

FC speed capabilities for the optical transceiver.
Possible values: "1", "2", "4", "8" in Gb/s.

Revision

Revision for the optical transceiver.

Firmware Revision

Firmware revision of the adapter.

Hardware Description

Description of the adapter (vendor and model).

Packet Size

FC packet size of adapter.

Established Connection

Type of connection established.
Possible values: "ptp" or "loop".

Port Address

Host port address of the adapter.

Menu Commands

Function

Description

FC Port Activity

Generates a report for one port.

Pause Monitoring

Pauses the monitoring of the selected object.

Resume Monitoring

Resumes the monitoring of the selected object.

Remove

Removes the selected object from the monitoring environment.