Icon
Parameters
|
|
|
|
|
OperationRate*
|
Total number of operations per second.
|
Operations/s
|
None
|
Statistics
|
Present
|
Indicates whether the device is still present or not since the last collect. This parameter is updated at each collect.
|
{0 = No; 1 = Yes}
|
0 = Alarm
|
Availability
|
ReadOperationRate
|
Number of read operations per second.
|
Operations/s
|
None
|
Statistics
|
ReadResponseTime
|
Average response time for read operations.
|
Milliseconds (ms)
|
Warning ≥ 30
Alarm ≥ 100
|
Response Time
|
ResponseTime*
|
Average response time for all operations.
|
Milliseconds (ms)
|
Warning ≥ 30
Alarm ≥ 100
|
Response Time
|
Status
|
Status of the disk.
|
{0 = OK; 1 = Degraded; 2 = Failed}
|
1 = Warning
2 = Alarm
|
Availability
|
StatusInformation
|
Detailed information about the disk status.
|
n/a
|
None
|
--
|
WriteOperationRate
|
Number of write operations per second.
|
Operations/s
|
None
|
Statistics
|
WriteResponseTime
|
Average response time for write operations.
|
Milliseconds (ms)
|
Warning ≥ 30
Alarm ≥ 100
|
Response Time
|
* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.
InfoBox
|
|
PATROL ID
|
Unique identifier of the object in the PATROL console.
|
Physical Size
|
Physical disk size in bytes.
|
Capacity
|
Disk capacity in MB.
|
Plex1
|
Plex to which the disk belongs.
|
Pool
|
Pool the disk is in.
|
RAID Group1
|
RAID group to which the disk belongs.
|
Port
|
Port of the disk.
|
RAID Type
|
RAID type. Possible values are: pending, parity, dparity, data, and unowned.
|
Vendor
|
Vendor of this disk.
|
Aggregate1
|
Aggregate on which the disk resides.
|
Model
|
Model name of the disk.
|
RAID State1
|
RAID state. Possible values are: "partner", "broken", "zeroing", "spare", "copy", "pending", "reconstructing", "present" and "unknown".
|
Shelf
|
Disk shelf.
|
Bay
|
Disk bay.
|
Serial Number
|
Disk serial number.
|
Speed
|
Rotational speed in revolutions per minute. Possible values are: 5400, 7200, 10000, and 15000.
This element is not returned when the value is not known, or when it does not apply.
|
Type
|
Type of the disk. Possible values are "ATA”, “BSAS”, “EATA”, “FCAL”, “FSAS”, “LUN”, “MSATA”, “SAS”, “SATA”, “SCSI”, “SSD”, “XATA”, “XSAS”, or “unknown”.
|
1 Parameter not available for NetApp Data ONTAP9 storage systems.
Menu Commands
|
|
Pause Monitoring
|
Pauses the monitoring of the selected object.
|
Resume Monitoring
|
Resumes the monitoring of the selected object.
|
Remove
|
Removes the selected object from the monitoring environment.
|
|