Name
Decription
Unit
Default Alert Conditions
Attribute Type
CIFSOperationRate
Number of CIFS operations per second.
Operations/s
None
Statistics
CollectionStatus
Status of the collection. Errors reported by this parameter are only related to NetApp Filers KM itself.
{0 = OK; 1 = Degraded; 2 = Failed}
Collection Status
CollectionStatusInformation
Detailed information about the collection status.
n/a
--
DiskTransferByteRate
Total bytes read and written per second to the disk.
Megabytes per second (MB/s)
FCPOperationRate
Number of FCP operations per second.
HTTPOperationRate
Number of HTTP operations per second.
iSCSIOperationRate
Number of iSCSI operations per second.
NetworkTransferByteRate*
Total bytes read and written per second through the network.
NFSOperationRate
Number of NFS operations per second.
OperationRate
Total number of operations per second.
PortCount
Number of physical ports in the cluster.
Note: This value can be used to know the number of required licenses for the monitoring system.
Ports
PowerConsumption*
Reports the electricity consumption of the storage system.
Watts
SpareDiskCount
Number of spare disks in the storage system.
Disks
0 = Warning
Status
Status of the storage system.
1= Warning
2 = Alarm
Availability
StatusInformation
Detailed information about the storage system status.
* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.
Description
PATROL ID
Unique identifier of the object in the PATROL console.
FQDN
Meta Token to generate the device ID used by BPPM.
Inactive Licenses
List of inactive licenses.
MetaEntityType
System model, updated upon each discovery cycle (typically: Storage.NetApp).
Function
Reporting > Cluster Activity
Generates a report for the cluster.
Reporting > Nodes Activity
Generates a report for one or several nodes.
Reporting > Ethernet Ports Activity
Generates a report for one or several Ethernet ports.
Reporting > FC Ports Activity
Generates a report for one or several FC ports.
Reporting > Host Adapters Activity
Generates a report for one or several host adapters.
Reporting > NVRAM Activity
Generates a report for one or several NVRAM.
Reporting > Vservers Activity
Generates a report for one or several Vservers.
Reporting > Volumes Activity
Generates a report for one or several volumes.
Reporting > LUNs Activity
Generates a report for one or several LUNs.
Reporting > LUNs Mapping Table
Generates a table of mapped and unmapped LUNs.
Edit Connection Settings
Edits connection settings.
Discovery Interval
Customizes the discovery cycle. By default, discovery is performed every hour.
Polling Interval
Customizes the polling cycle. By default, the polling interval is done every 2 minutes.
Disable Volumes Monitoring
Disables the monitoring of all the volumes of a system.
Disable LUNs Monitoring
Disables the monitoring of all the LUNs of a system.
Pause Monitoring
Pauses the monitoring of the selected object.
Resume Monitoring
Resumes the monitoring of the selected object.
Remove
Removes the selected object from the monitoring environment.
Refresh Parameters
Refreshes all parameters of the application class.