Back to the list of classes

NetBackup Database

PATROL Class: NBU_DATABASE - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a backup catalog database.

Database monitoring is disabled on media servers and in passive multi-node mode.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Filesystem Space Used Percent NBUDatabaseFSSpaceUsedPercent %

 WARN
if ∈ [95 %, 98 %]

 ALARM
if ≥ 98 %

Monitors the percentage of space used by the file system where the catalog database resides.

Value set by NBUDatabaseCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Space Available NBUDatabaseSpaceAvailable MB

 ALARM
if ≤ 2 MB

 WARN
if ∈ [2 MB, 5 MB]

Monitors the amount of assigned space remaining for use by the catalog database.

Value set by NBUDatabaseCollector.

Type: Availability - Spikes expected

Space Growth Rate NBUDatabaseSpaceGrowthRate MB/s None

Displays the growth rate of the space used by the catalog database.

Value set by NBUDatabaseCollector.

Type: Statistics

Space Used NBUDatabaseSpaceUsed MB None

Displays the amount of space used by the catalog database.

Value set by NBUDatabaseCollector.

Type: Statistics - Spikes expected

Space Used Percent NBUDatabaseSpaceUsedPercent %

 WARN
if ∈ [95 %, 98 %]

 ALARM
if ≥ 98 %

Monitors the percentage of assigned space used by the catalog database.

Value set by NBUDatabaseCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Summary NBUDatabaseSummary N/A None

Summarizes the database information as reported in the commands executed by the data collector.

Value set by NBUDatabaseCollector.

Type: Text

No results.