Back to the list of classes

NetBackup Databases

PATROL Class: NBU_DATABASE_CONTAINER - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Groups all backup catalog databases.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Backup Elapsed NBUDatabaseBackupElapsed hours

 ALARM
if = -1 hours

 WARN
if ≥ 24 hours

Displays the elapsed time since the last successful catalog database backup.

Value set by NBUDatabaseCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Exec Time NBUDatabaseCollectorExecTime seconds None

This is a standard parameter which monitors the collector execution time.

It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below:

%PSL pconfig("REPLACE", "/Runtime/NBU/<node-id>/NBUDatabaseCollectorWarn", 3600);

Type: Collection Status - Spikes expected

Details NBUDatabaseDetails N/A None

Displays all data returned to the standard out from commands executed by the data collector.

Value set by NBUDatabaseCollector.

Type: Text

Status NBUDatabaseStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the status of the NetBackup database (NBDB).

Value set by NBUDatabaseCollector.

Type: Availability - Spikes expected

No results.