Back to the list of classes

NetBackup Robotic Library

PATROL Class: NBU_LIBRARY - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a robotic library.

Library monitoring is disabled in passive multi-node mode.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Media Assigned Count NBULibraryMediaAssignedCount count None

Displays the number of assigned media loaded in this robotic library. Assigned media are tape media assigned to a non-scratch volume pool.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed

Media Available Count NBULibraryMediaAvailableCount count None

Displays the number of media available to use in this robotic library. This includes unassigned and scratch media.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed

Media Available Percent NBULibraryMediaAvailablePercent %

 ALARM
if ≤ 2 %

 WARN
if ∈ [2 %, 5 %]

Monitors the percentage of available media against the total number of media loaded in this robotic library.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Media Cleaning Left NBULibraryMediaCleaningLeft count

 ALARM
if ≤ 0 count

 WARN
if ∈ [0 count, 2 count]

Monitors the number of cleaning left on the cleaning media available in this robotic library.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed

Media Count NBULibraryMediaCount count None

Displays the total number of media loaded in this robotic library.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed

Media Scratch Count NBULibraryMediaScratchCount count None

Displays the number of scratch media loaded in this robotic library. Scratch media are tape media assigned to the scratch volume pool.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed

Media Scratch Percent NBULibraryMediaScratchPercent % None

Monitors the percentage of scratch media against the total number of media loaded in this robotic library.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Media Unassigned Count NBULibraryMediaUnassignedCount count None

Displays the number of unassigned media loaded in this robotic library. Unassigned media are tape media not assigned to a volume pool.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed

Media Unassigned Percent NBULibraryMediaUnassignedPercent % None

Monitors the percentage of unassigned media against the total number of media loaded in this robotic library.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

State NBULibraryState 0 = Online
1 = Remote
2 = Offline
3 = Invalid
-1 = Unknown
None

Displays whether the inquiry for the robotic library is valid or invalid. It will not perform any remote robotic library test command on the media server.

Value set by NBULibraryCollector.

Type: Availability - Spikes expected

Status NBULibraryStatus 0 = OK
1 = Suspicious
2 = Failure

 WARN
if = 1 (Suspicious)

 ALARM
if = 2 (Failure)

Monitors the status of the robotic library. This status is determined by the robotic library status mapping configuration.

Value set by NBULibraryCollector.

Type: Availability - Spikes expected

Summary NBULibrarySummary N/A None

Summarizes the robotic library information as reported in the commands executed by the data collector.

Value set by NBULibraryCollector.

Type: Text

Throughput NBULibraryThroughput MB/s None

Displays the total throughput of each robotic library drive during the last backup activities within the last hour.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed - Default graph

Up Drive Count NBULibraryUpDriveCount count None

Displays the number up / online state drives in this robotic library.

Value set by NBULibraryCollector.

Type: Statistics - Spikes expected - Baselining allowed

No results.