EMC XtremIO Controller
PATROL Class: SEN_XTRM_CONTROLLER - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.
Monitors a specific controller
Attributes (Parameters)
Name | PATROL Name | Units | Default Thresholds | Description |
---|---|---|---|---|
Enable Status | EnableStatus | 0 = Enabled 1 = User Disabled 2 = System Disabled 3 = Unknown |
WARN ALARM |
Indicates whether the storage controller is enabled or disabled. Type: Availability - Spikes expected |
Fan Status | FanStatus | 0 = Clear 1 = Warning/Minor 2 = Major/Critical 3 = Unknown |
WARN ALARM |
Status of the least healthy fan. Type: Availability - Spikes expected |
FRU Lifecycle Status | FRULifecycleStatus | 0 = Healthy 1 = Initializing 2 = Failed/Disconnected/Uninitialized 3 = Unknown |
WARN ALARM |
Status of the Field Replaceable Unit. Type: Availability - Spikes expected |
Operation Rate | OperationRate | operations/s | None | Total number of operations per second. Type: Statistics - Spikes expected - Default graph |
Present | Present | 0 = No 1 = Yes |
ALARM |
Indicates whether the device is present or not since the last collect. Type: Availability - Spikes expected |
Read Byte Rate | ReadByteRate | MB/s | None | Bytes read per second from the controller since the last collect. Type: Statistics - Spikes expected |
Read Operation Rate | ReadOperationRate | operations/s | None | Number of read operations per second. Type: Statistics - Spikes expected |
Status | Status | 0 = Healthy 1 = Partial Fault 2 = Degraded/Failed 3 = Unknown |
WARN ALARM |
Overall health status of the controller and its components. Type: Availability - Spikes expected |
Status Information | StatusInformation | None | None | Detailed information about the controller status. Type: Text |
Temperature Status | TemperatureStatus | 0 = Clear 1 = Warning/Minor 2 = Major/Critical 3 = Unknown |
WARN ALARM |
Status of the least healthy temperature sensor. Type: Availability - Spikes expected |
Transfer Byte Rate | TransferByteRate | MB/s | None | Total bytes read and written per second to the storage controller. Type: KPI - Statistics - Spikes expected |
Voltage Status | VoltageStatus | 0 = Clear 1 = Warning/Minor 2 = Major/Critical 3 = Unknown |
WARN ALARM |
Status of the least healthy voltage sensor. Type: Availability - Spikes expected |
Write Byte Rate | WriteByteRate | MB/s | None | Bytes written per second to the controller since the last collect. Type: Statistics - Spikes expected |
Write Operation Rate | WriteOperationRate | operations/s | None | Number of write operations per second. Type: Statistics - Spikes expected |
Infoboxes (PATROL Console Only)
Name | Description |
---|---|
PATROL ID | The PATROL internal identifier. |
Serial Number | Controller serial number. |
Management Address | Controller management address. |
Port Count | Number of ports. |
SSD Count | Number of SSDs. |
Local Disk Count | Number of local disks. |
Menu Commands (PATROL Console Only)
Menu Command | Description |
---|---|
Reporting > Controller Activity... | Enables you to generate a report on the controller activity. |
Reporting > Ports Activity... | Enables you to generate a report on the ports activity. |
Pause Monitoring | Pauses the monitoring of the controller. |
Resume Monitoring | Resumes the monitoring of the controller after it has been paused. |
Remove | Removes the controller from the monitoring environment. |