EMC XtremIO Controller
PATROL Class: SEN_XTRM_CONTROLLER - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.
Monitors a specific controller
Attributes (Parameters)
| Name | PATROL Name | Units | Default Thresholds | Description |
|---|---|---|---|---|
| Enable Status | EnableStatus | 0 = Enabled 1 = User Disabled 2 = System Disabled 3 = Unknown |
WARN ALARM |
Indicates whether the storage controller is enabled or disabled. Type: Availability - Spikes expected |
| Fan Status | FanStatus | 0 = Clear 1 = Warning/Minor 2 = Major/Critical 3 = Unknown |
WARN ALARM |
Status of the least healthy fan. Type: Availability - Spikes expected |
| FRU Lifecycle Status | FRULifecycleStatus | 0 = Healthy 1 = Initializing 2 = Failed/Disconnected/Uninitialized 3 = Unknown |
WARN ALARM |
Status of the Field Replaceable Unit. Type: Availability - Spikes expected |
| Operation Rate | OperationRate | operations/s | None | Total number of operations per second. Type: Statistics - Spikes expected - Default graph |
| Present | Present | 0 = No 1 = Yes |
ALARM |
Indicates whether the device is present or not since the last collect. Type: Availability - Spikes expected |
| Read Byte Rate | ReadByteRate | MB/s | None | Bytes read per second from the controller since the last collect. Type: Statistics - Spikes expected |
| Read Operation Rate | ReadOperationRate | operations/s | None | Number of read operations per second. Type: Statistics - Spikes expected |
| Status | Status | 0 = Healthy 1 = Partial Fault 2 = Degraded/Failed 3 = Unknown |
WARN ALARM |
Overall health status of the controller and its components. Type: Availability - Spikes expected |
| Status Information | StatusInformation | None | None | Detailed information about the controller status. Type: Text |
| Temperature Status | TemperatureStatus | 0 = Clear 1 = Warning/Minor 2 = Major/Critical 3 = Unknown |
WARN ALARM |
Status of the least healthy temperature sensor. Type: Availability - Spikes expected |
| Transfer Byte Rate | TransferByteRate | MB/s | None | Total bytes read and written per second to the storage controller. Type: KPI - Statistics - Spikes expected |
| Voltage Status | VoltageStatus | 0 = Clear 1 = Warning/Minor 2 = Major/Critical 3 = Unknown |
WARN ALARM |
Status of the least healthy voltage sensor. Type: Availability - Spikes expected |
| Write Byte Rate | WriteByteRate | MB/s | None | Bytes written per second to the controller since the last collect. Type: Statistics - Spikes expected |
| Write Operation Rate | WriteOperationRate | operations/s | None | Number of write operations per second. Type: Statistics - Spikes expected |
Infoboxes (PATROL Console Only)
| Name | Description |
|---|---|
| PATROL ID | The PATROL internal identifier. |
| Serial Number | Controller serial number. |
| Management Address | Controller management address. |
| Port Count | Number of ports. |
| SSD Count | Number of SSDs. |
| Local Disk Count | Number of local disks. |
Menu Commands (PATROL Console Only)
| Menu Command | Description |
|---|---|
| Reporting > Controller Activity... | Enables you to generate a report on the controller activity. |
| Reporting > Ports Activity... | Enables you to generate a report on the ports activity. |
| Pause Monitoring | Pauses the monitoring of the controller. |
| Resume Monitoring | Resumes the monitoring of the controller after it has been paused. |
| Remove | Removes the controller from the monitoring environment. |
xtremio km patrol