Back to the list of classes

EMC XtremIO Controller

PATROL Class: SEN_XTRM_CONTROLLER - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a specific controller

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Enable Status EnableStatus 0 = Enabled
1 = User Disabled
2 = System Disabled
3 = Unknown

 WARN
if = 1 (User Disabled)

 ALARM
if ∈ [2 (System Disabled), 3 (Unknown)]

Indicates whether the storage controller is enabled or disabled.

Type: Availability - Spikes expected

Fan Status FanStatus 0 = Clear
1 = Warning/Minor
2 = Major/Critical
3 = Unknown

 WARN
if = 1 (Warning/Minor)

 ALARM
if ∈ [2 (Major/Critical), 3 (Unknown)]

Status of the least healthy fan.

Type: Availability - Spikes expected

FRU Lifecycle Status FRULifecycleStatus 0 = Healthy
1 = Initializing
2 = Failed/Disconnected/Uninitialized
3 = Unknown

 WARN
if = 1 (Initializing)

 ALARM
if ∈ [2 (Failed/Disconnected/Uninitialized), 3 (Unknown)]

Status of the Field Replaceable Unit.

Type: Availability - Spikes expected

Operation Rate OperationRate operations/s None

Total number of operations per second.

Type: Statistics - Spikes expected - Default graph

Present Present 0 = No
1 = Yes

 ALARM
if = 0 (No)

Indicates whether the device is present or not since the last collect.

Type: Availability - Spikes expected

Read Byte Rate ReadByteRate MB/s None

Bytes read per second from the controller since the last collect.

Type: Statistics - Spikes expected

Read Operation Rate ReadOperationRate operations/s None

Number of read operations per second.

Type: Statistics - Spikes expected

Status Status 0 = Healthy
1 = Partial Fault
2 = Degraded/Failed
3 = Unknown

 WARN
if = 1 (Partial Fault)

 ALARM
if ∈ [2 (Degraded/Failed), 3 (Unknown)]

Overall health status of the controller and its components.

Type: Availability - Spikes expected

Status Information StatusInformation None None

Detailed information about the controller status.

Type: Text

Temperature Status TemperatureStatus 0 = Clear
1 = Warning/Minor
2 = Major/Critical
3 = Unknown

 WARN
if = 1 (Warning/Minor)

 ALARM
if ∈ [2 (Major/Critical), 3 (Unknown)]

Status of the least healthy temperature sensor.

Type: Availability - Spikes expected

Transfer Byte Rate TransferByteRate MB/s None

Total bytes read and written per second to the storage controller.

Type:  KPI - Statistics - Spikes expected

Voltage Status VoltageStatus 0 = Clear
1 = Warning/Minor
2 = Major/Critical
3 = Unknown

 WARN
if = 1 (Warning/Minor)

 ALARM
if ∈ [2 (Major/Critical), 3 (Unknown)]

Status of the least healthy voltage sensor.

Type: Availability - Spikes expected

Write Byte Rate WriteByteRate MB/s None

Bytes written per second to the controller since the last collect.

Type: Statistics - Spikes expected

Write Operation Rate WriteOperationRate operations/s None

Number of write operations per second.

Type: Statistics - Spikes expected

Infoboxes (PATROL Console Only)

Name Description
PATROL ID The PATROL internal identifier.
Serial Number Controller serial number.
Management Address Controller management address.
Port Count Number of ports.
SSD Count Number of SSDs.
Local Disk Count Number of local disks.
Menu Command Description
Reporting > Controller Activity... Enables you to generate a report on the controller activity.
Reporting > Ports Activity... Enables you to generate a report on the ports activity.
Pause Monitoring Pauses the monitoring of the controller.
Resume Monitoring Resumes the monitoring of the controller after it has been paused.
Remove Removes the controller from the monitoring environment.
Keywords:
xtremio km patrol