Back to the list of classes

EMC XtremIO DAE

PATROL Class: SEN_XTRM_DAE - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a specific DAE

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
FRU Lifecycle Status FRULifecycleStatus 0 = Healthy
1 = Initializing
2 = Failed/Disconnected/Uninitialized
3 = Unknown

 WARN
if = 1 (Initializing)

 ALARM
if ∈ [2 (Failed/Disconnected/Uninitialized), 3 (Unknown)]

Status of the Field Replaceable Unit.

Type: Availability - Spikes expected

Object Severity ObjectSeverity 0 = Clear/Information
1 = Minor
2 = Major/Critical
3 = Unknown

 WARN
if = 1 (Minor)

 ALARM
if ∈ [2 (Major/Critical), 3 (Unknown)]

Severity level of the current alerts for the monitored device.

Type: Availability - Spikes expected

Present Present 0 = No
1 = Yes

 ALARM
if = 0 (No)

Indicates whether the device is present or not since the last collect.

Type: Availability - Spikes expected

Status Information StatusInformation None None

Detailed information about the DAE status.

Type: Text

Infoboxes (PATROL Console Only)

Name Description
PATROL ID The PATROL internal identifier.
Firmware Version Version of the Disk Array Enclosure's firmware.
Serial Number The Disk Array Enclosure's serial number.
DAE Model Disk Array Enclosure's model.
Menu Command Description
Pause Monitoring Pauses the monitoring of the selected object.
Resume Monitoring Resumes the monitoring of the selected object.
Remove Removes the selected object from the monitoring environment.
Keywords: