Back to the list of classes

EMC XtremIO Port

PATROL Class: SEN_XTRM_PORT - Monitor Type: MONITOR - Monitor Category: System
CDM Class: BMC_NetworkPort

Monitors a specific port.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Bandwidth Utilization BandwidthUtilization % None

Percentage used of the available bandwidth.

Type: Statistics - Spikes expected

FC CRC Errors FCCRCErrors errors

 WARN
if ≥ 1 errors

Number of invalid CRCs since the last collect.

Type: Statistics - Spikes expected

FC Link Failures FCLinkFailures failures

 WARN
if ≥ 1 failures

Number of link failures since the last collect.

Type: Statistics - Spikes expected

FC Loss Of Signal FCLossOfSignal losses

 WARN
if ≥ 1 losses

Number of signal losses since the last collect.

Type: Statistics - Spikes expected

FC Loss Of Synch FCLossOfSynch losses

 WARN
if ≥ 1 losses

Number of synchronization losses since the last collect.

Type: Statistics - Spikes expected

Inbound Bandwidth Utilization InboundBandwidthUtilization % None

Percentage of inbound bandwidth used on the port (received bytes).

Type: Statistics - Spikes expected

iSCSI Received CRC Errors iSCSIReceivedCRCErrors errors

 WARN
if ≥ 1 errors

The number of Ethernet frames received with CRC error (only for iSCSI ports).

Type: Statistics - Spikes expected

iSCSI Transmitted Errors iSCSITransmittedErrors errors

 WARN
if ≥ 1 errors

The number of packets that failed to be transmitted due to error (only for iSCSI ports) .

Type: Statistics - Spikes expected

Link Status LinkStatus 0 = Up
1 = Down/Unknown

 ALARM
if = 1 (Down/Unknown)

Indicates whether the link is up or down.

Type: Availability - Spikes expected

Operation Rate OperationRate operations/s None

Total number of operations per second.

Type: Statistics - Spikes expected - Default graph

Outbound Bandwidth Utilization OutboundBandwidthUtilization % None

Percentage of outbound bandwidth used on the port (sent bytes).

Type: Statistics - Spikes expected

Present Present 0 = No
1 = Yes

 ALARM
if = 0 (No)

Indicates whether the device is present or not since the last collect.

Type: Availability - Spikes expected

Read Operation Rate ReadOperationRate operations/s None

Number of read operations per second.

Type: Statistics - Spikes expected

Read Response Time ReadResponseTime ms

 WARN
if ≥ 20 ms, 5 times in a row

Response time for the read operations.

Type: Response Time - Spikes expected

Received Byte Rate ReceivedByteRate MB/s None

Bytes received per second.

Type: Statistics - Spikes expected

Response Time ResponseTime ms

 WARN
if ≥ 20 ms, 5 times in a row

Average response time for all operations.

Note: A number of 10 (or less) collected I/Os between two data collects being insufficient to accurately report on response time, EMC XtremIO KM may automatically sets this parameter to 0 to avoid triggering irrelevant alarms.

Type: Response Time - Spikes expected - Default graph

Sent Byte Rate SentByteRate MB/s None

Bytes sent per second.

Type: Statistics - Spikes expected

Status Status 0 = Clear/Information
1 = Minor
2 = Major/Critical
3 = Unknown

 WARN
if = 1 (Minor)

 ALARM
if ∈ [2 (Major/Critical), 3 (Unknown)]

The current status of the port.

Type: Availability - Spikes expected

Status Information StatusInformation None None

Detailed information about the port status.

Type: Text

Transfer Byte Rate TransferByteRate MB/s None

Count of data transferred per second.

Type: Statistics - Spikes expected - Default graph

Write Operation Rate WriteOperationRate operations/s None

Number of write operations per second.

Type: Statistics - Spikes expected

Write Response Time WriteResponseTime ms

 WARN
if ≥ 20 ms, 5 times in a row

Response time for the write operations.

Type: Response Time - Spikes expected

Infoboxes (PATROL Console Only)

Name Description
PATROL ID The PATROL internal identifier.
Type Indicates the type of the port.
WWN WWN address of the port on the SAN.
MTU Maximum Transmission Unit..
Bandwidth Bandwidth of the storage switch port.
Menu Command Description
Acknowledge Error Count Alerts and Reset Acknowledges the alert and resets the error count to zero.
Port Activity... Enables you to generate a report on the port activity.
Pause Monitoring Pauses the monitoring of the selected object.
Resume Monitoring Resumes the monitoring of the selected object.
Remove Removes the selected object from the monitoring environment.
Keywords: