Back to the list of classes

EMC XtremIO PSU

PATROL Class: SEN_XTRM_PSU - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors a specific PSU.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Enable Status EnableStatus 0 = Enabled
1 = User Disabled
2 = System Disabled
3 = Unknown

 WARN
if = 1 (User Disabled)

 ALARM
if ∈ [2 (System Disabled), 3 (Unknown)]

Indicates whether the Power Supply Unit is enabled or disabled.

Type: Availability - Spikes expected

Firmware Version Error FirmwareVersionError None None

Indicates if the firmware or OS upgrade has failed or is in the process of upgrading.

Type: Text

FRU Lifecycle Status FRULifecycleStatus 0 = Healthy
1 = Initializing
2 = Failed/Disconnected/Uninitialized
3 = Unknown

 WARN
if = 1 (Initializing)

 ALARM
if ∈ [2 (Failed/Disconnected/Uninitialized), 3 (Unknown)]

Status of the Field Replaceable Unit.

Type: Availability - Spikes expected

Input Power InputPower 0 = On
1 = NA
2 = Off

 WARN
if = 1 (NA)

 ALARM
if = 2 (Off)

Indicates the existence of input power to the Power Supply Unit.

Type: Statistics - Spikes expected

Object Severity ObjectSeverity 0 = Clear/Information
1 = Minor
2 = Major/Critical
3 = Unknown

 WARN
if = 1 (Minor)

 ALARM
if ∈ [2 (Major/Critical), 3 (Unknown)]

Severity level of the current alerts for the monitored device.

Type: Availability - Spikes expected

Power Failure PowerFailure None None

Indicates severity according to the nature of a power failure.

Type: Text

Present Present 0 = No
1 = Yes

 ALARM
if = 0 (No)

Indicates whether the device is present or not since the last collect.

Type: Availability - Spikes expected

Status Information StatusInformation None None

Detailed information about the Power Supply Unit status.

Type: Text

Infoboxes (PATROL Console Only)

Name Description
PATROL ID The PATROL internal identifier.
Firmware Version Version of the Power Supply Unit's firmware.
Serial Number The Power Supply Unit's serial number.
Model Power Supply Unit model.
Location The location of the Power Supply Unit.
Menu Command Description
Pause Monitoring Pauses the monitoring of the selected object.
Resume Monitoring Resumes the monitoring of the selected object.
Remove Removes the selected object from the monitoring environment.
Keywords:
xtremio km patrol