Back to the list of classes

Hardware Enclosure

PATROL Class: MS_HW_ENCLOSURE - Monitor Type: MONITOR - Monitor Category: System
CDM Class: BMC_ComputerSystem -- Instances of this monitor will be represented as devices in TrueSight Operations Management

Monitors a hardware enclosure, such as a computer's main chassis, external disk arrays or blade enclosures.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Intrusion Status IntrusionStatus 0 = OK
2 = Intrusion Detected
None

Monitors the intrusion status of the enclosure. If the enclosure is open or not properly closed, it is set to Intrusion Detected.

Value set by enclosureColl.

Type: Availability

Power Consumption PowerConsumption Watts None

This parameter reports the electricity consumption.

Value set by enclosureColl.

Type: Statistics - Default graph

Power State PowerState 0 = Off
1 = Suspended
2 = On
None

The enclosure current power state: on, off or suspended.

Value set by enclosureColl.

Type: Availability

Present Present 0 = Missing
1 = Present

 ALARM
if = 0 (Missing)

Indicates whether the enclosure is found or not.

Value set by enclosureColl.

Type: Availability

Status Status 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Current status of the enclosure.

Value set by enclosureColl.

Type: Availability

Status Information StatusInformation None None

Additional (textual) information about the current status of the enclosure.

Value set by enclosureColl.

Type: Text

No results.