SEN_NAP_7_CONTROLLER

Home  Previous  Next

Icon

sen_nap_controller_ok_32

Parameters

Name

Description

Unit

Default Alert Conditions

Attribute Type

CIFSOperationRate

Total number of CIFS operations per second.

Operations/s

None

Statistics

DiskReadByteRate

Bytes read per second from the disk since the last collect.

Megabytes per second (MB/s)

None

Statistics

DiskTransferByteRate* Auto Baseline KPI

Total bytes read and written per second to the disk.

Megabytes per second (MB/s)

None

Statistics

DiskWriteByteRate

Bytes written per second to the disk since the last collect.

Megabytes per second (MB/s)

None

Statistics

FCPOperationRate

Total number of FCP operations per second.

Operations/s

None

Statistics

HTTPOperationRate

Total number of HTTP operations per second.

Operations/s

None

Statistics

iSCSIOperationRate

Total number of iSCSI operations per second.

Operations/s

None

Statistics

NetworkReceivedByteRate

Bytes received per second over the network.

Megabytes per second (MB/s)

None

Statistics

NetworkSentByteRate

Bytes sent per second over the network.

Megabytes per second (MB/s)

None

Statistics

NetworkTransferByteRate* Auto Baseline KPI

Total bytes transferred per second (sent and received) over the network.

Megabytes per second (MB/s)

None

Statistics

NFSOperationRate

Total number of NFS operations per second.

Operations/s

None

Statistics

OperationRate

Total number of operations per second.

Operations/s

None

Statistics

Present

Indicates whether the device is still present or not since the last collect. This parameter is updated at each collect.

{0 = No; 1 = Yes}

0 = Alarm

Availability

ProcessorUtilization

Percentage of utilization of the CPU resource.

Percentage (%)

Warning ≥ 80

Alarm ≥ 100

Statistics

ReadOperationRate

Number of read operations per second.

Operations/s

None

Statistics

ReadResponseTime

Average response time for read operations.

Milliseconds (ms)

Warning ≥ 30

Alarm ≥ 100

Response Time

ResponseTime

Average response time for all operations.

Milliseconds (ms)

Warning ≥ 30

Alarm ≥ 100

Response Time

WriteOperationRate

Number of write operations per second.

Operations/s

None

Statistics

WriteResponseTime

Average response time for write operations.

Milliseconds (ms)

Warning ≥ 30

Alarm ≥ 100

Response Time

* Parameters marked with an asterisk are used by default when visualizing the corresponding monitor instance in TrueSight Operations Management.

InfoBox

Name

Description

PATROL ID

Unique identifier of the object in the PATROL console.

Hostname

Hostname of the system.

Host ID

System ID defined by the vendor.

Host Address

Location of the controller in a multi-controller platform. Defined by the platform layer. Possible values are A,B,C…

Serial Number

System serial number.

Model

Model name of the controller.

Vendor

Hardware vendor identifier.

Partner System Name

Partner's system name. Displayed in a cluster environment. Defined in the partner's setup.

System Revision

Revision ID of the system board.

Number of Processors

Number of processors in the device.

Active Processors

Number of active processors in the system.

Memory Size

Size of the controller's memory in megabytes.

Menu Commands

Function

Description

Reporting > Controller Activity

Generates a report for one or several controllers.

Reporting > iSCSI Activity

Generates a report for one or several iSCSI ports.

Reporting > Host Adapters Activity

Generates a report for one or several host adapters.

Reporting > FC Ports Activity

Generates a report for one or several FC ports.

Reporting > Ethernet Ports Activity

Generates a report for one or several Ethernet ports.

Reporting > NVRAM Activity

Generates a report for one or several NVRAM.

Pause Monitoring

Pauses the monitoring of the selected object.

Resume Monitoring

Resumes the monitoring of the selected object.

Remove