VxVM Disk Groups
PATROL Class: VVM_DISKGROUP_CONTAINER - Monitor Type: CONTAINER - Monitor Category: System
No CDM Class defined.
Groups all VxVM disk groups.
Attributes (Parameters)
| Name | PATROL Name | Units | Default Thresholds | Description |
|---|---|---|---|---|
| Disk Device Exec Time | VVMDiskDeviceCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/VVM/<node-id>/VVMDiskDeviceCollectorWarn", 3600); Type: Collection Status - Spikes expected |
| Disk Device Details | VVMDiskDeviceDetails | N/A | None | Displays all data returned to the standard out from the commands executed by the data collector. Value set by VVMDiskDeviceCollector. Type: Text |
| Disk Group Exec Time | VVMDiskGroupCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/VVM/<node-id>/VVMDiskGroupCollectorWarn", 3600); Type: Collection Status - Spikes expected |
| Disk Group Details | VVMDiskGroupDetails | N/A | None | Displays all data returned to the standard out from the commands executed by the data collector. Value set by VVMDiskGroupCollector. Type: Text |
| Plex Exec Time | VVMPlexCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/VVM/<node-id>/VVMPlexCollectorWarn", 3600); Type: Collection Status - Spikes expected |
| Plex Details | VVMPlexDetails | N/A | None | Displays all data returned to the standard out from the commands executed by the data collector. Value set by VVMPlexCollector. Type: Text |
| Rlink Exec Time | VVMRlinkCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/VVM/<node-id>/VVMRlinkCollectorWarn", 3600); Type: Collection Status - Spikes expected |
| Rlink Details | VVMRlinkDetails | N/A | None | Displays all data returned to the standard out from the commands executed by the data collector. Value set by VVMRlinkCollector. Type: Text |
| Rvg Exec Time | VVMRvgCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/VVM/<node-id>/VVMRvgCollectorWarn", 3600); Type: Collection Status - Spikes expected |
| Rvg Details | VVMRvgDetails | N/A | None | Displays all data returned to the standard out from the commands executed by the data collector. Value set by VVMRvgCollector. Type: Text |
| Subdisk Exec Time | VVMSubdiskCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/VVM/<node-id>/VVMSubdiskCollectorWarn", 3600); Type: Collection Status - Spikes expected |
| Subdisk Details | VVMSubdiskDetails | N/A | None | Displays all data returned to the standard out from the commands executed by the data collector. Value set by VVMSubdiskCollector. Type: Text |
| Volume Exec Time | VVMVolumeCollectorExecTime | seconds | None | This is a standard parameter which monitors the collector execution time. It will run every minute and trigger a warning when the collector runs for more than the observed maximum time. This maximum time can be overridden by a preset value (example: 3600 seconds), using the PSL below: %PSL pconfig("REPLACE", "/Runtime/VVM/<node-id>/VVMVolumeCollectorWarn", 3600); Type: Collection Status - Spikes expected |
| Volume Details | VVMVolumeDetails | N/A | None | Displays all data returned to the standard out from the commands executed by the data collector. Value set by VVMVolumeCollector. Type: Text |