P1304 - Cisco Telnet Switches - Incorrect numbering of Fans

Mar 29, 2012
Patch for Hardware Sentry KM for PATROL - Version(s) 1.6.00,1.6.01,1.7.00,1.7.01,1.8.00

Download File

Patch content

Connector for Cisco Fibre Switches

Should you install this patch?

Apply this patch if:

You are seeing chassis fans with IDs:

  • ChassisFan11
  • ChassisFan22
  • etc...
or if you require the name of the host each port is connected to.

What does it fix?

The connector will no longer add a unique identifier to Chassis Fans if they already have one.

The connector adds hostname to "Connected to Physical Address" property of the FC Port

How to install the patch?

  1. Copy the following file to the %PATROL_HOME%\lib\MS_HW_hdf directory on the managed server:
    • MS_HW_CiscoTelnet.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect.
  3. Nothing needs to be installed on Console systems.