P1306 - Detection Criteria Failing for IBM Director 6.2.1 Agents
Mar 29, 2012Download File
Patch content
Connectors for IBM Director 6.x on Linux Servers
Should you install this patch?
Apply this patch if the "SMI-S Compliant RAID Controller - Linux" is working and you are getting the following error message for the IBM Director 6.x Connector:
- Failed to make the following WBEM Query:
WQL query: SELECT Name FROM __NAMESPACE
What does it fix?
The detection criteria query "SELECT Name FROM __NAMESPACE" has been removed as it was causing the connector to fail unnecessarily.
How to install the patch?
- Copy the following file to the $PATROL_HOME/lib/MS_HW_hdf directory on the managed server:
- MS_HW_Director61Linux.hdf
- Re-initialize Hardware Sentry for the patch to take effect.
- Nothing needs to be installed on Console systems.