Patches

P1306 - Detection Criteria Failing for IBM Director 6.2.1 Agents

Mar 29, 2012
Patch for Hardware Sentry KM for PATROL - Version(s) 1.6.00,1.6.01,1.7.00,1.7.01,1.8.00

Download File

Patch content

Connectors for IBM Director 6.x on Linux Servers

Should you install this patch?

Apply this patch if the "SMI-S Compliant RAID Controller - Linux" is working and you are getting the following error message for the IBM Director 6.x Connector:

  • Failed to make the following WBEM Query:
    WQL query: SELECT Name FROM __NAMESPACE

What does it fix?

The detection criteria query "SELECT Name FROM __NAMESPACE" has been removed as it was causing the connector to fail unnecessarily.

How to install the patch?

  1. Copy the following file to the $PATROL_HOME/lib/MS_HW_hdf directory on the managed server:
    • MS_HW_Director61Linux.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect.
  3. Nothing needs to be installed on Console systems.