Patches

P1340 - IBM Director 6.3 or Later: Missing Temperature and Voltage Thresholds

Aug 30, 2012
Patch for Hardware Sentry KM for PATROL - Version(s) 1.6.00,1.6.01,1.7.00,1.7.01,1.8.00

Download File

Patch content

Connectors for IBM Director 6

Should you install this patch?

Apply this patch if you are using version 6.3 or later of the IBM Director Agent and if Temperature and / or Voltage thresholds are missing.

What does it fix?

Temperature and voltage thresholds are stored in a different property depending on the version of the IBM Director Agent used. This patch takes in consideration both pre 6.3 and 6.3 threshold properties.

How to install the patch?

  1. Copy the following files to the %PATROL_HOME%/lib/MS_HW_hdf directory on the managed server:
    • MS_HW_Director61NT.hdf
    • MS_HW_Director61Linux.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect ([right-click] on the main Hardware Sentry icon > [KM Commands] > [Reinitialize KM...]).
  3. Nothing needs to be installed on Console systems.