Patches

P1371 - Connector for HP StorageWorks MSA 2000 & P2000

Oct 30, 2012
Patch for BMC Performance Manager Express for Hardware - Version(s) 2.7.00,2.7.03,2.7.05,2.7.13,2.7.17,2.7.26,2.7.28

Download File

Patch content

Connector for HP StorageWorks MSA 2000 & P2000.

Should you install this patch?

Apply this patch if the connector is activated but does not return any enclosure or components or if the MIB2 connector only is activated.

This patch replaces patches P1314 and P1330.

What does it fix?

Discovery stopped when the string "#" was found in the xml command output; this string was identified as the prompt, which caused the capturing of the full output of the command to stop.

How to install the patch?

On each RSM, copy the MS_HW_HPDotHill.hdf file to %RSM_HOME%\RSMxx\SEN_HW\hdf_27xx\