Patches

P1485 - Bad Temperature and Voltage Thresholds in IBM xSeries Servers

Oct 03, 2013
Patch for BMC Performance Manager Express for Hardware - Version(s) 2.7.13,2.7.17,2.7.26,2.7.28,2.9.00

Download File

Patch content

Connectors for IBM Director Agent 6 – Windows and for IBM Director Agent 6 - Linux.

Should you install this patch?

Install this patch if you are getting incorrect temperature and/or voltage thresholds on IBM xSeries servers running the IBM Director Agent.

What does it fix?

The 6.3.2 version of the IBM Director agent reports voltage and temperature alert thresholds in a way that is inconsistent with the previous versions. The new connector takes into account this variation and support older and newer versions of the IBM Director Agent.

How to install the patch?

Copy the following files to %RSM_HOME%\RSMxx\SEN_HW\hdf_2x\ on each RSM:

  • MS_HW_Director61Linux.hdf
  • MS_HW_Director61NT.hdf
No further actions are required. The new component monitoring will be added at the next discovery.