Patches

P1615 - Monitoring Cisco UCS Interconnect Switches connected to C-Series

Mar 02, 2015
Patch for Hardware Sentry KM for PATROL - Version(s) 1.8.00,1.8.01,1.8.02,1.9.00

Download File

Patch content

Connector for Cisco UCS Manager (Blade, Fabric Interconnect Switch)

Should you install this patch?

Install this patch if you have Cisco UCS Interconnect Switches that are only connected to Cisco C-Series servers.

What does it fix?

The connector will now activate when a Cisco UCS Interconnect Switch is detected. A B-Series UCS Chassis was previously required.

How to install the patch?

  1. Copy the following file to the $PATROL_HOME/lib/MS_HW_hdf directory on the server where the PATROL Agent runs:
    • MS_HW_CiscoUCSBlade.hdf
  2. Re-initialize Hardware Sentry for the patch to take effect.
  3. Nothing needs to be installed on Console systems.