P1661 - Warning Notification on Decreasing AvailablePathCount for LUNs
Jun 19, 2015Download File
Patch content
PSL library
Should you install this patch?
Install this patch on servers where the AvailablePathCount parameter of the MS_HW_LUN application class is activated.
What does it fix?
Hardware Sentry 1.9.00 was configured to trigger an "Alarm" on all instances of the MS_HW_LUN application class when the number of available paths reached 0. This patch adds a second alert level, dynamically tailored to each instance, which triggers a "Warning" when the number of available paths is one path lower than the initial number of available paths.
How to install the patch?
- Copy the following file to the $PATROL_HOME/lib/psl or %PATROL_HOME%\lib\psl directory on the server where the PATROL Agent runs:
- MS_HW_luns.lib
- Restart the PATROL Agent for the patch to take effect. Nothing needs to be installed on Console systems.