Back to the list of classes

Hardware Disk Controller

PATROL Class: MS_HW_DISKCONTROLLER - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.

Monitors the disk controller which connects one or more physical disk drives. This instance groups all physical and logical disk drives. If a controller goes missing all its disks will also become missing.

Attributes (Parameters)

Name PATROL Name Units Default Thresholds Description
Battery Status BatteryStatus 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Current status of the disk controller battery. A weak disk controller battery will be unable to support the controller in the event of a power failure.

Value set by diskControllerColl.

Type: Availability - Default graph

Controller Status ControllerStatus 0 = OK
1 = Degraded
2 = Failed

 WARN
if = 1 (Degraded)

 ALARM
if = 2 (Failed)

Current status of the disk controller.

Value set by diskControllerColl.

Type: Availability - Default graph

Present Present 0 = Missing
1 = Present

 ALARM
if = 0 (Missing)

Indicates whether the disk controller is found or not.

Value set by diskControllerColl.

Type: Availability

Status Information StatusInformation None None

Additional (textual) information about the current status of the disk controller.

Value set by diskControllerColl.

Type: Text

No results.