Hardware Disk Controller
PATROL Class: MS_HW_DISKCONTROLLER - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.
Monitors the disk controller which connects one or more physical disk drives. This instance groups all physical and logical disk drives. If a controller goes missing all its disks will also become missing.
Attributes (Parameters)
Name | PATROL Name | Units | Default Thresholds | Description |
---|---|---|---|---|
Battery Status | BatteryStatus | 0 = OK 1 = Degraded 2 = Failed |
WARN ALARM |
Current status of the disk controller battery. A weak disk controller battery will be unable to support the controller in the event of a power failure. Value set by diskControllerColl. Type: Availability - Default graph |
Controller Status | ControllerStatus | 0 = OK 1 = Degraded 2 = Failed |
WARN ALARM |
Current status of the disk controller. Value set by diskControllerColl. Type: Availability - Default graph |
Present | Present | 0 = Missing 1 = Present |
ALARM |
Indicates whether the disk controller is found or not. Value set by diskControllerColl. Type: Availability |
Status Information | StatusInformation | None | None | Additional (textual) information about the current status of the disk controller. Value set by diskControllerColl. Type: Text |