Hardware LUN
PATROL Class: MS_HW_LUN - Monitor Type: MONITOR - Monitor Category: System
No CDM Class defined.
Monitors a specific LUN, which are volumes stored on a remote disk array and that are exposed to the operating system of a server as a hard disk by the HBA card (host bus adapter, typically a fiber channel card).
Note: In most redundant systems, a LUN can be accessed through different paths. Hardware Sentry checks the multi-path I/O (MPIO), if configured, to identify and monitor the unique LUNs.
Attributes (Parameters)
Name | PATROL Name | Units | Default Thresholds | Description |
---|---|---|---|---|
Available Path Count | AvailablePathCount | paths | None | Number of distinct paths available to the remote volume. Value set by lunColl. Type: Statistics - Default graph |
Available Path Information | AvailablePathInformation | None | None | Textual information about the paths to the remote volume. Value set by lunColl. Type: Text |
Status | Status | 0 = OK 1 = Degraded 2 = Failed |
WARN ALARM |
Availability of the remote volume. Value set by lunColl. Type: Availability - Default graph |
Status Information | StatusInformation | None | None | Additional (textual) information about the current status of the LUN. Value set by lunColl. Type: Text |