Back to the list of connectors
Adaptec - StorMan - RAID
Description
Gives information about physical disks and volumes of Adaptec SAS RAID controllers through the arcconf utility.
Connector ID: AdptStorManUnix
Target
Typical platform: Any system with Adaptec
Operating systems: Oracle Solaris, Linux
Prerequisites
Leverages: arcconf
Technology and protocols: System Commands
This connector requires advanced privileges on the managed host for the command below:
/[opt|usr]/StorMan/arcconf
This connector therefore needs to run as root or you need to configure a privilege-escalation mechanism like sudo
on the managed host to allow the monitoring account to run the command listed above.
Sample of /etc/sudoers to allow the above command to be run as root by the hwsagent account:
hwsagent ALL=(root) NOPASSWD: /[opt|usr]/StorMan/arcconf
Examples
CLI
hws HOSTNAME -t solaris -f AdptStorManUnix --ssh -u USER --sudo-command-list /[opt|usr]/StorMan/arcconf
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: solaris
selectedConnectors: [ AdptStorManUnix ] # Optional, to load only this connector
ssh:
username: <USERNAME> # Change with actual credentials
password: <PASSWORD> # Encrypted using hws-encrypt
useSudo: true
useSudoCommands: [ "/[opt|usr]/StorMan/arcconf" ]
Connector Activation Criteria
The Adaptec - StorMan - RAID connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- Operating System is Oracle Solaris or Linux
- The command below succeeds on the monitored host
- Command:
/bin/sh %EmbeddedFile(1)%
- Output contains:
Hard drive
(regex)
- Command:
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Disk Controller |
|
|
Battery |
|
|
Logical Disk, RAID |
|
|
Physical Disk |
|
|