Back to the list of connectors
Data Domain Storage Appliance (SNMP)
Description
This connector discovers the enclosure and the disks of Data Domain disk arrays as well as the various environment sensors (temperatures, fans, power supplies). It relies on the SNMP protocol.
Connector ID: DataDomain
Target
Typical platform: Data Domain
Operating system: Storage System
Prerequisites
Leverages: Data Domain SNMP Agent
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
hws HOSTNAME -t storage -f DataDomain --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: storage
selectedConnectors: [ DataDomain ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The Data Domain Storage Appliance (SNMP) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.19746.1
must return a value in the same subtree
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Battery |
|
|
Fan |
|
|
Logical Disk, RAID |
|
|
Physical Disk |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|