Back to the list of connectors

Dell OpenManage Array Manager

Description

This connector provides disks monitoring through the Dell OpenManage Array Manager SNMP agent (not to be confused with Storage Manager).

Connector ID: DellArrayManager

Target

Typical platform: Dell PowerEdge

Operating systems: Microsoft Windows, Linux

Prerequisites

Leverages: Dell OpenManage Server Administrator

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f DellArrayManager --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ DellArrayManager ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Dell OpenManage Array Manager connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.674.10893.1.1.130.4.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Disk Controller
  • hw.status{hw.type="disk_controller",state="present"}
  • firmware_version
  • model
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Physical Disk
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="present"}
  • serial_number
  • vendor
No results.