Back to the list of connectors

Dell OpenManage Storage Manager

Description

This connector provides Dell disk array monitoring through the Dell Storage Manager Agent which supports almost all Dell disk arrays.

Connector ID: DellStorageManager

This connector supersedes:

Target

Typical platform: Dell PowerEdge

Operating systems: Microsoft Windows, Linux

Prerequisites

Leverages: Dell OpenManage Server Administrator

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f DellStorageManager --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ DellStorageManager ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Dell OpenManage Storage Manager connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.674.10893.1.20 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="ok|degraded|failed"}
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • type
  • vendor
Disk Controller
  • hw.status{hw.type="disk_controller",state="ok|degraded|failed"}
  • hw.status{hw.type="disk_controller",state="present"}
  • driver_version
  • firmware_version
  • model
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
  • model
  • vendor
Fan
  • hw.fan.speed
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • info
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Other Device
  • hw.status{hw.type="other_device",state="ok|degraded|failed"}
  • hw.status{hw.type="other_device",state="present"}
  • info
  • device_type
Physical Disk
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="predicted_failure"}
  • hw.status{hw.type="physical_disk",state="present"}
  • info
  • serial_number
  • vendor
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
  • info
Temperature Sensor
  • hw.status{hw.type="temperature",state="ok|degraded|failed"}
  • hw.status{hw.type="temperature",state="present"}
  • hw.temperature
    No results.