Back to the list of connectors
Dell iDRAC - Server
Description
This connector provides hardware monitoring through Dell's iDRAC Management Card for Dell servers with iDRAC7 or later.
Connector ID: DelliDRACServer
This connector is superseded by:
Target
Typical platform: Dell PowerEdge
Operating system: Out-of-Band
Prerequisites
Leverages: Dell iDRAC Management Card (iDRAC7 or Later)
Technology and protocols: SNMP
Examples
CLI
hws HOSTNAME -t management -f DelliDRACServer --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ DelliDRACServer ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The Dell iDRAC - Server connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get-Next on the OID
1.3.6.1.4.1.674.10892.5.4
must return a value in the same subtree
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|
Enclosure |
|
|
Battery |
|
|
Processor |
|
|
Fan |
|
|
Memory Module |
|
|
Network Card, FC Port |
|
|
Other Device |
|
|
Power Supply |
|
|
Temperature Sensor |
|
|
Voltage Sensor |
|
|