Back to the list of connectors

IBM Director Agent 6 - Windows

Description

This connector provides hardware monitoring through the IBM Director Agent version 6

Connector ID: Director61NT

This connector supersedes:

Target

Typical platform: IBM xSeries

Operating system: Microsoft Windows

Prerequisites

Leverages: IBM Director Agent 6

Technology and protocols: WMI

Examples

CLI

hws HOSTNAME -t win -f Director61NT --wmi -u USER

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ Director61NT ] # Optional, to load only this connector
  wmi:
    username: <USERNAME> # Change with actual credentials
    password: <PASSWORD> # Encrypted using hws-encrypt

Connector Activation Criteria

The IBM Director Agent 6 - Windows connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • Operating System is Microsoft Windows
  • The WMI query below to the managed host succeeds:
    • Namespace: root
    • WQL Query: SELECT Name FROM __NAMESPACE
    • Result contains: ^ibmsd;*$ (regex)
  • The WMI query below to the managed host succeeds:
    • Namespace: root\ibmsd
    • WQL Query: SELECT Version FROM IBMPSG_DirectorAgent
    • Result contains: \(^6\.1\.[2-9].*\)\|\(^6\.[2-9].*\) (regex)
  • The WMI query below to the managed host succeeds:
    • Namespace: root\ibmsd
    • WQL Query: SELECT ProductName FROM IBMPSG_ComputerSystemDetails

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Processor
  • hw.cpu.speed.limit{limit_type="max"}
  • hw.status{hw.type="cpu",state="ok|degraded|failed"}
  • hw.status{hw.type="cpu",state="present"}
  • model
Fan
  • hw.fan.limit{limit_type="high.critical"}
  • hw.fan.limit{limit_type="high.degraded"}
  • hw.fan.speed
  • hw.status{hw.type="fan",state="present"}
    Memory Module
    • hw.memory.limit
    • hw.status{hw.type="memory",state="ok|degraded|failed"}
    • hw.status{hw.type="memory",state="present"}
    • info
    Power Supply
    • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
    • hw.status{hw.type="power_supply",state="present"}
      Temperature Sensor
      • hw.status{hw.type="temperature",state="present"}
      • hw.temperature
      • hw.temperature.limit{limit_type="high.critical"}
      • hw.temperature.limit{limit_type="high.degraded"}
        Voltage Sensor
        • hw.status{hw.type="voltage",state="present"}
        • hw.voltage
        • hw.voltage.limit{limit_type="high.critical"}
        • hw.voltage.limit{limit_type="low.critical"}
        • sensor_location
        No results.