Back to the list of connectors

Adaptec Storage Manager (DPT)

Description

This connector provides disk monitoring through the Adaptec Storage Manager SNMP sub-agent which supports all DPT-based Adaptec RAID controllers.

Connector ID: DptStorageManager

Target

Typical platform: Fujitsu-Siemens PRIMERGY

Operating systems: Microsoft Windows, Linux

Prerequisites

Leverages: Adaptec Storage Manager

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f DptStorageManager --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ DptStorageManager ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Adaptec Storage Manager (DPT) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.1597.1.2.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Disk Controller
  • hw.status{hw.type="disk_controller",state="present"}
  • bios_version
  • firmware_version
  • model
  • vendor
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Physical Disk
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="predicted_failure"}
  • hw.status{hw.type="physical_disk",state="present"}
  • serial_number
  • vendor
No results.