Back to the list of connectors

Dell EqualLogic PS Series

Description

Because multiple PS Systems can be managed by the same controller, the connector can discover multiple enclosures.

Connector ID: Equallogic

Target

Typical platform: Dell EqualLogic

Operating system: Storage System

Prerequisites

Leverages: Dell EqualLogic SNMP Agent (EQLGROUP-MIB)

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t storage -f Equallogic --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ Equallogic ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Dell EqualLogic PS Series connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.12740.2.1.11.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="present"}
  • info
  • model
  • serial_number
  • type
  • vendor
Disk Controller
  • hw.status{hw.type="disk_controller",state="present"}
  • firmware_version
  • model
  • serial_number
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
  • type
Fan
  • hw.fan.limit{limit_type="high.critical"}
  • hw.fan.limit{limit_type="high.degraded"}
  • hw.fan.speed
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • sensor_location
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
    Physical Disk
    • hw.errors{hw.type="physical_disk"}
    • hw.physical_disk.size
    • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
    • hw.status{hw.type="physical_disk",state="present"}
    • info
    • firmware_version
    • model
    • serial_number
    Power Supply
    • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
    • hw.status{hw.type="power_supply",state="present"}
    • power_supply_type
    Temperature Sensor
    • hw.status{hw.type="temperature",state="ok|degraded|failed"}
    • hw.status{hw.type="temperature",state="present"}
    • hw.temperature
    • hw.temperature.limit{limit_type="high.critical"}
    • hw.temperature.limit{limit_type="high.degraded"}
    • sensor_location