Fibre Alliance SNMP Agent (Switches)

Description

This connector discovers the enclosure and fiber-channel ports of SAN switches as well as the various environment sensors (temperatures, fans, power supplies, etc.). It relies on the SNMP protocol and supports the Fibre Alliance MIB (FCMGMT-MIB).

Connector ID: FibreAllianceSwitch

This connector is superseded by:

This connector supersedes:

Target

Typical platform: Any SAN switch

Operating system: Storage System

Prerequisites

Leverages: Fibre Alliance SNMP Agent (FCMGMT-MIB)

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t storage -f FibreAllianceSwitch --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: storage
  selectedConnectors: [ FibreAllianceSwitch ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Fibre Alliance SNMP Agent (Switches) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.3.94.1.6.1.3 must return a value in the same subtree and contains \(^4$\)\|\(^14$\) (regex)

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • serial_number
  • type
  • vendor
Fan
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • sensor_location
Network Card, FC Port
  • hw.errors{hw.type="network"}
  • hw.network.bandwidth.limit
  • hw.network.bandwidth.utilization
  • hw.network.full_duplex
  • hw.network.io{direction="receive"}
  • hw.network.io{direction="transmit"}
  • hw.network.packets{direction="receive"}
  • hw.network.packets{direction="transmit"}
  • hw.network.up
  • hw.status{hw.type="network",state="ok|degraded|failed"}
  • hw.status{hw.type="network",state="present"}
  • physical_address
  • remote_physical_address
  • serial_number
  • vendor
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
  • power_supply_type
Temperature Sensor
  • hw.status{hw.type="temperature",state="ok|degraded|failed"}
  • hw.status{hw.type="temperature",state="present"}
  • sensor_location
No results.