Back to the list of connectors

Fujitsu-Siemens ServerView RAID Agent

Description

This connector provides disk monitoring through the Fujitsu-Siemens Serverview RAID SNMP sub-agent which supports many RAID controllers in Primergy servers.

Connector ID: FscRaid

This connector supersedes:

Target

Typical platform: Fujitsu-Siemens PRIMERGY

Operating systems: Microsoft Windows, Linux

Prerequisites

Leverages: Fujitsu-Siemens Serverview RAID Agent

Technology and protocols: SNMP

Examples

CLI

hws HOSTNAME -t win -f FscRaid --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: win
  selectedConnectors: [ FscRaid ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Fujitsu-Siemens ServerView RAID Agent connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get-Next on the OID 1.3.6.1.4.1.231.2.49.1.5.2.1 must return a value in the same subtree

Metrics

Type Collected Metrics Specific Attributes (Labels)
Disk Controller
  • hw.status{hw.type="disk_controller",state="present"}
  • bios_version
  • firmware_version
  • model
  • vendor
Battery
  • hw.status{hw.type="battery",state="ok|degraded|failed"}
  • hw.status{hw.type="battery",state="present"}
  • type
Logical Disk, RAID
  • hw.logical_disk.limit
  • hw.status{hw.type="logical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="logical_disk",state="present"}
  • raid_level
Physical Disk
  • hw.errors{hw.type="physical_disk"}
  • hw.physical_disk.size
  • hw.status{hw.type="physical_disk",state="ok|degraded|failed"}
  • hw.status{hw.type="physical_disk",state="predicted_failure"}
  • hw.status{hw.type="physical_disk",state="present"}
  • serial_number
  • vendor
No results.