Back to the list of connectors
Fujitsu-Siemens Management Blade (FSC BX Blade Servers)
Description
This connector provides hardware monitoring through the Fujitsu-Siemens Management Blade SNMP Agent which supports the Fujitsu-Siemens Blade servers (BX300, BX600, etc.). Needs to run remotely.
Connector ID: FujitsuSiemensBlade
Target
Typical platform: Fujitsu-Siemens BX Blade
Operating system: Out-of-Band
Prerequisites
Leverages: Fujitsu-Siemens Management Blade
Technology and protocols: SNMP
This connector is not available for the local host (it is applicable to remote hosts only).
Examples
CLI
hws HOSTNAME -t management -f FujitsuSiemensBlade --snmp v2c --community public
hws-config.yaml
hosts:
- host:
hostname: <HOSTNAME> # Change with actual host name
type: management
selectedConnectors: [ FujitsuSiemensBlade ] # Optional, to load only this connector
snmp:
version: v1 # Read documentation for v2 and v3
community: public # or probably something more secure
Connector Activation Criteria
The Fujitsu-Siemens Management Blade (FSC BX Blade Servers) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:
- An SNMP Get on the OID
1.3.6.1.4.1.7244.1.1.1.1.12.1.0
must return a value that matches with the3
regular expression
Metrics
Type | Collected Metrics | Specific Attributes (Labels) |
---|---|---|