Fujitsu-Siemens Management Blade (FSC BX Blade Servers)

Description

This connector provides hardware monitoring through the Fujitsu-Siemens Management Blade SNMP Agent which supports the Fujitsu-Siemens Blade servers (BX300, BX600, etc.). Needs to run remotely.

Connector ID: FujitsuSiemensBlade

Target

Typical platform: Fujitsu-Siemens BX Blade

Operating system: Out-of-Band

Prerequisites

Leverages: Fujitsu-Siemens Management Blade

Technology and protocols: SNMP

This connector is not available for the local host (it is applicable to remote hosts only).

Examples

CLI

hws HOSTNAME -t management -f FujitsuSiemensBlade --snmp v2c --community public

hws-config.yaml

hosts:
- host:
    hostname: <HOSTNAME> # Change with actual host name
    type: management
  selectedConnectors: [ FujitsuSiemensBlade ] # Optional, to load only this connector
  snmp:
    version: v1 # Read documentation for v2 and v3
    community: public # or probably something more secure

Connector Activation Criteria

The Fujitsu-Siemens Management Blade (FSC BX Blade Servers) connector will be automatically activated, and its status will be reported as OK if all the below criteria are met:

  • An SNMP Get on the OID 1.3.6.1.4.1.7244.1.1.1.1.12.1.0 must return a value that matches with the 3 regular expression

Metrics

Type Collected Metrics Specific Attributes (Labels)
Enclosure
  • hw.status{hw.type="enclosure",state="present"}
  • model
  • type
  • vendor
Blade
  • hw.status{hw.type="blade",state="ok|degraded|failed"}
  • hw.status{hw.type="blade",state="present"}
  • model
Fan
  • hw.fan.speed
  • hw.status{hw.type="fan",state="ok|degraded|failed"}
  • hw.status{hw.type="fan",state="present"}
  • sensor_location
Power Supply
  • hw.status{hw.type="power_supply",state="ok|degraded|failed"}
  • hw.status{hw.type="power_supply",state="present"}
  • power_supply_type
Temperature Sensor
  • hw.status{hw.type="temperature",state="present"}
  • hw.temperature
  • hw.temperature.limit{limit_type="high.critical"}
  • hw.temperature.limit{limit_type="high.degraded"}
  • sensor_location